2-wire HART 7 temperature transmitter

 

6437A

 

  • RTD, TC, potentiometer, linear resistance and bipolar mV input
  • Single or true dual inputs with sensor redundancy and drift detection
  • Wide ambient operating temperature of -50 to +85°C
  • Total accuracy from 0.014%
  • 2.5 kVAC galvanic isolation
  • Full assessment to IEC61508 : 2010 for use in SIL 2/3 applications
Zone2 Ex Iec Iecex Zone2 SIL 2 SIL 3 Fmapprovedcus Zone2 CSA Inmetro Dekra NEPSI Dnv Eu Ro Eac Ex EAC UKCA CE
  1. Overview + -

  2. Technical details + -

  3. Accessories + -

  4. Order and delivery + -

  5. Why choose PR + -

Application

  • Temperature measurement of a wide range of TC and RTD types.
  • Conversion of wide span linear resistance and potentiometer inputs to 4...20 mA.
  • Conversion of bipolar mV signals to 4...20 mA.
  • Integration into asset management schemes.
  • Critical applications requiring superior accuracy and/or sensor redundancy and drift detection.

Technical characteristics

  • True dual input transmitter, accepts the widest range of dual input combinations.
  • Sensor redundancy - output automatically switches to secondary sensor in event of primary sensor failure, maintaining uptime.
  • Sensor drift detection - alerts when sensor differential exceeds user-defined limits, for maintenance optimization.
  • Dynamic variable mapping for process data in addition to the primary variable e.g. dual input features such as average, differential and min./max. tracking.
  • Groundbreaking digital and analog signal accuracy over full input span and ambient conditions.
  • Extensive sensor matching including Callendar Van Dusen and custom linearizations.
  • Programmable input limits with runtime metering ensure maximum process traceability and sensor out of range protection.
  • IEC 61508 : 2010 full assessment up to SIL 3 together with enhanced EMC Functional Safety testing to IEC 61236-3-1.
  • 6437xxSx is suitable for the use in systems up to Performance Level “d” according to ISO-13849.
  • Meets NAMUR NE21, NE43, NE44, NE89 and NE107 compliant diagnostics information.

Mounting / installation / programming

  • DIN rail mounting with up to 84 inputs per meter.
  • Configuration via PReset using PR5909 Loop Link /HART modem, or by Asset Management tool (e.g. Pactware, AMS, HART communicator).
  • The 6437A can be mounted in zone 2 and zone 22 / Class I, Division 2, Groups A, B, C, D.

Data sheet & Manuals


Data sheet

Manuals

Manuals in Russian

Supplementary documentation


EU Declaration of Conformity

UKCA Declaration of Conformity

Download Software

Environmental Conditions

Operating temperature -50°C to +85°C (standard) -40°C to +80°C (SIL)
Storage temperature -50°C to +85°C
Calibration temperature 23...25°C
Relative humidity < 99% RH (non-cond.)
Protection degree IP20

Mechanical specifications

Dimensions (HxWxD) 109 x 23.5 x 104 mm
Weight (single input / dual input) 150 g / 160 g
Wire size 0.13...2.08 mm2 AWG 26...14 stranded wire
DIN rail type DIN EN 60715/35 mm
Screw terminal torque 0.5 Nm
Vibration IEC 60068-2-6
2...25 Hz ±1.6 mm
25...100 Hz ±4 g

Common specifications

Supply

Supply voltage 7.5*...48** VDC
Power dissipation, per channel ≤ 850 mW
Additional min. supply voltage when using test terminals 0.8 V
Min. load resistance at >37 V supply (Vsupply – 37) / 23 mA

Isolation voltage

Isolation voltage, test / working 2.5 kVAC / 55 VAC

Response time

Response time 75 ms
Programmable damping 0...60 s
Polarity protection All inputs and outputs
Warm-up time < 5 min.
Start-up time < 2.75 s
Programming Loop Link & HART
Write protection Jumper or software
Signal / noise ratio > 60 dB
Long-term stability, better than ±0.05% of span / year (±0.18% of span / 5 years)
Signal dynamics, input 24 bit
Signal dynamics, output 18 bit
Effect of supply voltage change < 0.005% of span / VDC
Accuracy See manual for details
EMC immunity influence < ±0.1% of span
Extended EMC immunity: NAMUR NE21, A criterion, burst < ±1%

Input specifications

RTD input

RTD type Pt10...10000, Ni10...10000, Cu5...1000
Basic accuracy, e.g. Pt100 ≤ ±0.04°C
Cable resistance per wire 50 Ω (max.)
Effect of sensor cable resistance (3-/4-wire) < 0.002 Ω / Ω
Sensor current < 0.15 mA
Sensor error detection None, Shorted, Broken, Shorted or Broken

TC input

Thermocouple type B, E, J, K, L, N, R, S, T, U, W3, W5, LR
Basic accuracy, e.g. TC K ≤ ±0.25°C
Cold junction compensation (CJC) Constant, internal or external via a Pt100 or Ni100 sensor
Sensor error detection None, Shorted, Broken, Shorted or Broken

Linear resistance input

Measurement range / min. range (span) 0 Ω...100 kΩ / 25 Ω
Cable resistance per wire (max.) 50 Ω
Sensor current < 0.15 mA
Sensor error detection None, Broken

Potentiometer input

Potentiometer min....max. 10 Ω...100 kΩ
Measurement range / min. range (span) 0...100% / 10%
Cable resistance per wire (max.) 50 Ω
Sensor current < 0.15 mA
Sensor error detection None, Shorted, Broken, Shorted or Broken

mV input

Measurement range -800...+800 mV (bipolar) -100 to 1700 mV
Min. measurement range (span) 2.5 mV
Input resistance 10 MΩ
Sensor error detection None, Broken

Output specifications

Common output specifications

Normal range, programmable 3.8...20.5 / 20.5...3.8 mA
Extended range (output limits), programmable 3.5...23 / 23...3.5 mA
Basic accuracy ≤ ±1.6 μA (0.01% of full output span)
Updating time 10 ms
Load (@ current output) ≤ (Vsupply -7.5)/0.023 [Ω]
Load stability < 0.01% of span / 100 Ω
Sensor error indication Programmable 3.5…23 mA
NAMUR NE 43 Upscale/Downscale > 21 mA / < 3.6 mA
HART protocol revisions HART 7 and HART 5

Observed authority requirements

EMC 2014/30/EU & UK SI 2016/1091 2014/30/EU
RoHS 2011/65/EU & UK SI 2012/3032
ATEX 2014/34/EU & UK SI 2016/1107
EAC TR-CU 020/2011
EAC Ex TR-CU 012/2011

Approvals

ATEX DEKRA 18ATEX0135X
IECEx IECEx DEK. 16.0029X
CSA CSA 16.70066266
c FM us FM16US0287X / FM16CA0146X
INMETRO DEKRA 16.0008 X
NEPSI GYJ18.1057X
EAC Ex EAEU KZ 7500361.01.01.08756
EU RO MR Type Approval MRA0000023
SIL SIL 2 / SIL 3 certified & fully assessed acc. to IEC 61508

NB

* / ** See manual for details

 

Need support to select the right product for your application?

Our sales engineers are ready to help specify the right device to meet your needs.

 

Reach out by phone to get in touch with us straight away – or use the contact form or quick quote function to send your RFQ directly from the website. You’ll get a response within 24 hours on normal business days.

 

You can expect to get a confirmed delivery date via email within 2 days after we have received your order.

 

As soon as your package leaves our warehouse, you’ll receive tracking details via email. And if you have any questions along the way we’re just a phone call or email away.

 

State-of-the-art manufacturing

State-of-the-art manufacturing

Our 8,500 sqm integrated and automated manufacturing campus in Denmark covers the entire value-chain from design and development to manufacturing. It allows us to design and optimize for testing and manufacturing thereby constantly driving quality up and costs down.

 

Dedicated Presales / Aftersales

Dedicated Presale / Aftersales
Our more than 80 dedicated sales engineers can help specify the right device for your application. Backed by our 9 subsidiaries and more than 40 dedicated partners, we are directly accessible in more than 40 countries around the world.

 

Find a PR location close to you

 

Product reliability

Product reliability
Although we’d always like to be top of mind, we recognize our job is mainly to provide peace of mind. Install & Forget® is our way of saying that once installed, our devices will continue to perform even in the toughest environments. And we are not afraid to back that statement up with commitments.

 

Product deployment

Product deployment
Our devices are intuitive and simple to configure. Once installed they visualize rich diagnostics data, allowing the operator to plan preventative maintenance, maximizing process up-time.

 

 

Smart products

Smart products
Many of our devices are designed to accommodate current and future communication enablers, providing the operator with multifunctional capabilities that extends into the future.

 

Check out our range of communication interfaces

 

Smart products

 

Your request has been sent successfully. 0 items on your list
Your contact information

Company information

Please insert your company name.
Please insert your company address
Please insert a valid zip code
Please insert a city
Please select country

Your information

Please insert your last name
Please insert your last name
Please insert a valid email address
Please insert a valid phone number. Use only numbers.
Please insert your job title
Please read and agree with PR electronics’ Privacy Policy.
Get an answer within 24 hours

A mistake has occurred. Please call us instead

You have not added any products to your quote list
When browsing the website, you can add products to a quote list by simply clicking “Add to quote list" on the individual product pages. Once all relevant products are included, send the list to us and you will get a quotation within 24 hours. If you don't submit the list, it will be accessible on the website for 21 days. We hope you will find the functionality useful.
Thank you for requesting a quotation. We will get back to you by phone or email within 24 hours.
Service Red

If you need support, you are always welcome to contact us

Service Red
Newsletter Icon Red

Register here to receive our newsletter

Newsletter Icon Red