Ex power supply
5420B
- 2 channels
- 5-port 3.75 kVAC galvanic isolation
- Output voltage > 18 V to I.S. area
- Active current loop detection
- Universal supply by AC or DC
Application
- Voltage supply with safety barrier for the supply of equipment mounted in hazardous area.
- Voltage supply with failsafe detection of active current loop from 2-wire transmitters mounted in hazardous area.
Technical characteristics
- PR5420B has a relay with change-over contacts available in the safe area. When the loop current is within the defined limit, the relay is ON.
- Supply and outputs are floating and galvanically separated.
Mounting / installation
- Mounted vertically or horizontally on a DIN rail. Up to 84 channels per meter can be mounted.
Note
- Not suitable for new installations requiring certification to the latest ATEX standards - see ATEX certificate DEMKO 99ATEX126256 and EU Declaration of Conformity for details.
Ficha técnica y manuales
Ficha técnica
- 5420B.pdf
- Última versión
Manuales
- 5420BV102_UK.pdf
- 5420BV101.pdf
- 5420BV100.pdf
- Versiones anteriores
- Última versión
Manuales en ruso
- 5420BV102_RU.pdf
- Última versión
Homologaciones y certificados
Certificado ATEX
- 5420B.pdf
- Última versión
Declaración EAC
- EAC_EMC_declaration_Ex_3000_5000_6000_9000.pdf
- Última versión
Certificado EAC
- EAC_Ex.pdf
- Última versión
Metrology Pattern Approval (MPA), Russia
- MPA_Russia.pdf
- Última versión
Documentación complementaria
Declaración UE de conformidad
- 5420DoC_EU_102_UK.pdf
- 5420DoC_EU_101_UK.pdf
- 5420DoC_EU_100_UK.pdf
- Versiones anteriores
- Última versión
Nota de seguridad
Nota de seguridad
- SN5000-3_103_1933.pdf
- SN5000-3_102_1613.pdf
- SN5000_101_1450.pdf
- Versiones anteriores
- Última versión
Formulario de pedido
Environmental Conditions
Operating temperature | -20°C to +60°C |
Calibration temperature | 20...28°C |
Relative humidity | < 95% RH (non-cond.) |
Protection degree | IP20 |
Mechanical specifications
Dimensions (HxWxD) | 109 x 23.5 x 130 mm |
Weight approx. | 215 g |
DIN rail type | DIN 46277 |
Wire size | 1 x 2.5 mm2 stranded wire |
Screw terminal torque | 0.5 Nm |
Common specifications
Supply |
|
Supply voltage, universal | 21.6...253 VAC, 50...60 Hz or 19.2...300 VDC |
Max. required power | ≤ 4 W (2 channels) |
Internal power dissipation | ≤ 2 W (2 channels) |
Fuse | 400 mA SB / 250 VAC |
Isolation voltage |
|
Isolation voltage, test / working | 3.75 kVAC / 250 VAC |
PELV/SELV | IEC 61140 |
EMC immunity influence | < ±0.5% |
Extended EMC immunity: NAMUR NE21, A criterion, burst | < ±1% |
Output specifications
Relay output |
|
Max. voltage | 250 VRMS |
Max. current | 2 ARMS |
Max. AC power | 100 VA |
Max. load at 24 VDC | 1 A |
Output voltage | > 18 VDC at 20 mA |
Output current | 28 mA per channel (max.) |
Relay outputs: On within limit | > 3.8...< 20.5 mA |
Observed authority requirements
EMC | 2014/30/EU |
LVD | 2014/35/EU |
EAC | TR-CU 020/2011 |
Approvals
ATEX | DEMKO 99ATEX126256, II (1) GD [EEx ia] IIC |
EAC Ex | EAEU KZ 7500361.01.01.08756 |
Need support to select the right product for your application?
Our sales engineers are ready to help specify the right device to meet your needs.
Reach out by phone to get in touch with us straight away – or use the contact form or quick quote function to send your RFQ directly from the website. You’ll get a response within 24 hours on normal business days.
You can expect to get a confirmed delivery date via email within 2 days after we have received your order.
As soon as your package leaves our warehouse, you’ll receive tracking details via email. And if you have any questions along the way we’re just a phone call or email away.
State-of-the-art manufacturing Our 8,500 sqm integrated and automated manufacturing campus in Denmark covers the entire value-chain from design and development to manufacturing. It allows us to design and optimize for testing and manufacturing thereby constantly driving quality up and costs down. |
Dedicated Presale / Aftersales
|
Product reliability |
Product deployment
|
Smart products
Check out our range of communication interfaces
|