Temperature transmitters
What is a temperature transmitter?
A temperature transmitter converts the small signal from a temperature sensor - typically a thermocouple or RTD - into a more robust 4...20 mA or digital signal for interfacing into other control equipment. To ensure accuracy a temperature transmitter is capable of isolating, amplifying, linearizing and filtering noise from the temperature sensor signal.
If you require assistance in selecting the device that is just right for your application, please do not hesitate to contact us.
- RTD, TC, Ohm, or mV input
- HART 5 protocol
- For DIN form B sensor head mounting
- RTD, TC, Ohm, and bipolar mV input
- HART 5 and HART® 7
- Mounting in Safe area or Zone 2/22
- RTD, TC, Ohm, and bipolar mV input
- HART 5 and HART 7
- Mounting in hazardous gas and dust area
- RTD or Ohm input
- Output 4...20 mA, with or without M12 connector
- Tube mounting, e.g. M18 barrel housing
- RTD, TC, Ohm, or mV input
- Extremely high measurement accuracy
- 1- or 2-channel version
- RTD, TC, Ohm, or mV input
- Extremely high measurement accuracy
- Installation in Ex zone 0
- RTD or Ohm input
- High measurement accuracy
- 1- or 2-channel version
- RTD or Ohm input
- High measurement accuracy
- Can be installed in Ex zone 0
- TC input
- High measurement accuracy
- 1- or 2-channel version
- TC input
- High measurement accuracy
- Can be installed in Ex zone 0
- RTD, TC, Ohm, or mV input
- HART 5 protocol
- 1- or 2-channel version
- RTD, TC, Ohm, or mV input
- HART 5 protocol
- Can be installed in Ex zone 0
- RTD, TC, Ohm, and bipolar mV input
- HART 5 and HART 7
- Mounting in Zone 2, 22 / Class I, Div. 2
- RTD, TC, Ohm, and bipolar mV input
- HART 5 and HART 7
- Mounting in hazardous gas and dust area
- 1 or 2 channels
- Can be supplied separately or installed on power rail, PR type 9400
- SIL 2-certified via Full Assessment
- 1 or 2 channels
- EMPHASIS assessed instrument for nuclear industry
- SIL 2-certified via Full Assessment
- Accuracy, IEC 60751 class A
- 1/2” RG connection
- Temperature range -50°C to +400°C
- For all PR head-mounted transmitters
- Aluminum or 316 stainless steel version
- Installation in harsh environments IP54-IP68
- Accuracy, IEC 60751 class A
- Ø 6 x 80 mm
- Ambient temperature range -40°C to +80°C
- For sensor head mounting
- Mounting in 7400xxxx sensor head
- All-purpose sensor / insert
- For tasks that require interchangeable inserts
- Ø6 x 60 mm
- Accuracy, IEC 60751 class A
- Wall-mounted
- Ambient temperature range -50°C to +80°C
A full range of temperature transmitter types are available including:
Head mounted temperature transmitters
Transmitters for DIN form B sensor head installation in temperature sensor assemblies.
DIN rail temperature transmitters
Single and dual channel transmitters for DIN rail installation.
Field mounted temperature transmitters with display
Field mounted transmitter with high-definition backlit display in aluminum or stainless-steel housing.
Compact M12 temperature transmitters
Compact RTD transmitter with or without M12 connector for installation in barrel housing.
From HART 7 digital temperature transmitters, offering dual input with sensor redundancy and advanced NE107 compliant diagnostics to a simple Pt100 RTD transmitter; PR electronics offers a wide range of market leading universal temperature transmitters, thermocouple temperature transmitters and RTD temperature transmitters to meet the demands of all temperature applications.
In addition, we can offer a one-stop integrated solution combining our temperature transmitters with sensors form our partners around the world.
Explore our range of temperature transmitters to find the perfect device for your temperature measurement requirements.