4512
Data sheet & Manuals
Data sheet
- 4512.pdf
- Latest version
Manuals
- 4512V103_UK.pdf
- 4512V102_UK.pdf
- 4512V101_UK.pdf
- 4512V100_UK.pdf
- Previous versions
- Latest version
Manuals in Russian
- 4512V103_RU.pdf
- 4512V102_RU.pdf
- 4512V101_RU.pdf
- 4512V100_RU.pdf
- Previous versions
- Latest version
Approvals & Certificates
ATEX certificate
- 4512_issue4.pdf
- Latest version
IECEx certificate
- 4512IEC_issue3.pdf
- Latest version
UKEX certificate
- 4512UKEX_Issue 0.pdf
- Latest version
FM certificate
- 4512_FM18US0268X_FM18CA0129X.pdf
- Latest version
Bluetooth certificate Australia
- BT_Australia_4512_issue01.pdf
- Latest version
Bluetooth certificate Brazil
- Anatel_Brazil_4512_issue01.pdf
- Latest version
Bluetooth certificate China
- SRRC_China_4512_issue01.pdf
- Latest version
Bluetooth certificate Peru
- BT_Peru_4512_issue01.pdf
- Latest version
Bluetooth certificate Singapore
- BT_Singapore_4512_2020.pdf
- Latest version
Bluetooth certificate Malaysia
- BT_Malaysia_4512_2020.pdf
- Latest version
EAC declaration
- EAC-Declaration.pdf
- Latest version
Supplementary documentation
EU Declaration of Conformity
- 4512DoC_EU_102_UK.pdf
- 4512DoC_EU_101_UK.pdf
- 4512DoC_EU_100_UK.pdf
- Previous versions
- Latest version
UKCA Declaration of Conformity
- 4512DoC_UKCA_100_UK.pdf
- Latest version
Supplemental information
- 4512_PPS_Supplemental_information_1.0.pdf
- Latest version
PR 4512 data logging capacity
- 4512_Data_logging_capacity_V1R0.pdf
- Latest version
Safety note
Safety note
- SN4500_106_2443.pdf
- SN4500_105_2239.pdf
- SN4512_101_2119.pdf
- SN4512_100_2007.pdf
- Previous versions
- Latest version
Environmental Conditions
Operating temperature | -20°C to +60°C |
Storage temperature | -20°C to +85°C |
Relative humidity | < 95% RH (non-cond.) |
Protection degree | IP20 |
Installation in | Pollution degree 2 & meas. / overvoltage cat. II |
Mechanical specifications
Dimensions (HxWxD) | 73.2 x 23.3 x 26.5 mm |
Dimensions (HxWxD) w/ 4000/9000 unit | 109 x 23.5 x 131 mm |
Weight approx. | 30 g |
Common specifications
Supply |
|
Supply voltage | 6.5...20 V supplied from host 4000 / 9000 device |
Max. required power | 0.15 W |
Data logging |
|
Memory | 100 MB |
Capacity | > 2.75 million data points (depending on the connected PR device) |
Data retention, without power | ~ 10 years |
Extended EMC immunity: NAMUR NE21, A criterion, burst | No loss of communication |
Internal battery back-up (for real-time clock) | 2 years (@ 25°C) |
Calibrated clock accuracy | <±60 s/year @ 25°C |
Bluetooth communication | BLE 4.2 |
Bluetooth radio | Class 2 |
I.S. / Ex marking
ATEX | II 3 G Ex ec IIC T5 |
IECEx | Ex ec IIC T5 Gc |
FM, US | Cl I, Div 2, Gp A, B, C, D T5; Cl I, Zn 2, Grp IIC T5 |
FM, CA | Cl I, Div 2, Gp A, B, C, D T5 |
Observed authority requirements
Directives |
|
EMC | 2014/30/EU & UK SI 2016/1091 |
ATEX | 2014/34/EU & UK SI 2016/1107 |
RED | 2014/53/EU & UK SI 2017/1206 |
RoHS | 2011/65/EU & UK SI 2012/3032 |
Standards |
|
Standard for Safety | ANSI/ISA 61010-1 : 2004 |
Bluetooth |
|
Europe, CE | 117-37823-1 |
USA, FCC | ID QoQBGM111 |
Canada, IC | 5123A-BGM111 |
China, SRRC | 2018DJ6574 |
Australia, RCM | 42 004 182 772 |
Brazil, Anatel | 06541-18-11723 |
Japan, MIC | R 209-J00192 |
Korea, KC | MSIP-CRM-BGT, BGM111 |
Malaysia, SIRIM QAS | RAHY/63M/1020/S(20-4544) |
Singapore, IMDA | N1861-20 |
EAC | TR-CU 020/2011 |
Approvals
ATEX | DEKRA 13ATEX0098 X |
IECEx | DEK 13.0026 X |
UKEX | DEKRA 21UKEX0167X |
c FM us | FM18US0268X / FM18CA0129X |