3105
Data sheet & Manuals
Data sheet
- 3105.pdf
- Latest version
Manuals
- 3100V111_UK.pdf
- 3100V110_UK.pdf
- 3100V109_UK.pdf
- 3100V108_UK.pdf
- 3100V107_UK.pdf
- 3100V105_UK.pdf
- 3100V100_UK.pdf
- Previous versions
- Latest version
Manuals in Russian
- 3100V111_RU.pdf
- 3100V110_RU.pdf
- 3100V109_RU.pdf
- 3100V108_RU.pdf
- 3100V107_RU.pdf
- 3100V106_RU.pdf
- Previous versions
- Latest version
Supplementary documentation
EU Declaration of Conformity
- 3105DoC_EU_105_UK.pdf
- 3105DoC_EU_104_UK.pdf
- 3105DoC_EU_103_UK.pdf
- 3105DoC_EU_102_UK.pdf
- 3105DoC_EU_101_UK.pdf
- 3105DoC_EU_100_UK.pdf
- Previous versions
- Latest version
UKCA Declaration of Conformity
- 3105DoC_UKCA_100_UK.pdf
- Latest version
EMC data
- 3000_EMC_data.pdf
- Latest version
Safety note
Safety note
Approvals & Certificates
UL certificate
- 3103-09_3117-18_3405.pdf
- Latest version
DNV marine certificate
- DNV_3xxx_TAA00001RW.pdf
- Latest version
EAC declaration
- EAC_EMC_declaration_Ex_3000_5000_6000_9000.pdf
- Latest version
Metrology Pattern Approval (MPA), Russia
- MPA_Russia.pdf
- Latest version
Environmental Conditions
Operating temperature | 0°C to +70°C |
Storage temperature | -40°C to +85°C |
Calibration temperature | 20...28°C |
Relative humidity | < 95% RH (non-cond.) |
Protection degree | IP20 |
Installation in | Pollution degree 2 & meas. / overvoltage cat. II |
Mechanical specifications
Dimensions (HxWxD) | 113 x 6.1 x 115 mm |
Weight approx. | 70 g |
DIN rail type | DIN EN 60715/35 mm |
Wire size | 0.13...2.5 mm2 / AWG 26...12 stranded wire |
Screw terminal torque | 0.5 Nm |
Vibration | IEC 60068-2-6 |
2...25 Hz | ±1.6 mm |
25...100 Hz | ±4 g |
Common specifications
Supply |
|
Supply voltage | 16.8...31.2 VDC |
Max. required power | 0.80 W |
Max. power dissipation | 0.52 W |
Isolation voltage |
|
Isolation voltage, test / working | 2.5 kVAC / 300 VAC (reinforced) |
Response time |
|
Response time (0...90%, 100...10%) | < 7 ms |
Programming | DIP-switches |
Signal / noise ratio | > 60 dB |
Cut-off frequency (3 dB) | > 100 Hz |
Signal dynamics, input | Analog signal chain |
Signal dynamics, output | Analog signal chain |
Accuracy | Better than 0.2% of selected range |
Temperature coefficient | < ±0.015% of span / ˚C |
EMC immunity influence | < ±0.5% of span |
Extended EMC immunity: NAMUR NE21, A criterion, burst | < ±1% of span |
Input specifications
Current input |
|
Measurement range | 0...23 mA |
Programmable measurement ranges | 0...20 and 4...20 mA |
Input voltage drop | < 1.5 VDC |
Voltage input |
|
Measurement range |
0...10.25 V
0...11.5 V / 0...5.75 V |
Programmable measurement ranges | 0/1...5 and 0/2...10 V |
Input resistance | ≥ 500 kΩ |
Output specifications
Current output |
|
Signal range | 0...23 mA |
Programmable signal ranges | 0 / 4...20 mA |
Load (@ current output) | ≤ 600 Ω |
Load stability | ≤ 0.002% of span / 100 Ω |
Current limit | ≤ 28 mA |
Voltage output |
|
Signal range | 0...10 VDC |
Programmable signal ranges | 0/1...5 and 0/2...10 V |
Load (@ voltage output) | ≥ 10 kΩ |
of span | = of the DIP-switch selected output range |
Observed authority requirements
EMC | 2014/30/EU & UK SI 2016/1091 |
LVD | 2014/35/EU & UK SI 2016/1101 |
RoHS | 2011/65/EU & UK SI 2012/3032 |
EAC | TR-CU 020/2011 |
Approvals
c UL us, UL 61010-1 | E314307 |
DNV Marine | TAA00001RW |