5225A
Data sheet & Manuals
Safety note
Safety note
- SN5000-3_103_1933.pdf
- SN5000-3_102_1613.pdf
- SN5000_101_1450.pdf
- Previous versions
- Latest version
Approvals & Certificates
EAC declaration
- EAC-Declaration.pdf
- Latest version
Metrology Pattern Approval (MPA), Russia
- MPA_Russia.pdf
- Latest version
Supplementary documentation
Environmental Conditions
Operating temperature | -20°C to +60°C |
Calibration temperature | 20...28°C |
Relative humidity | < 95% RH (non-cond.) |
Protection degree | IP20 |
Mechanical specifications
Dimensions (HxWxD) | 109 x 23.5 x 130 mm |
Weight approx. | 190 g |
DIN rail type | DIN 46277 |
Wire size | 1 x 2.5 mm2 stranded wire |
Screw terminal torque | 0.5 Nm |
Common specifications
Supply |
|
Supply voltage | 19.2...28.8 VDC |
Max. required power | 3.5 W |
Internal power dissipation | 1.7 W |
Isolation voltage |
|
PELV/SELV | IEC 61140 |
Warm-up time | 30 s |
Power-up delay | 0...999 s |
Programming | Loop Link |
Signal / noise ratio | Min. 60 dB |
Response time, analog | < 60 ms + period |
Response time, digital output | < 50 ms + period |
Response time, concurrent f/I and f/f | < 80 ms + period |
Signal dynamics, output | 16 bit |
Effect of supply voltage change | < ±0.002% of span / %V |
Auxiliary voltage: NAMUR supply | 8.3 VDC ±0.5 VDC / 8 mA |
S0 supply | 17 VDC / 20 mA |
NPN / PNP supply | 17 VDC / 20 mA |
Special supply (programmable) | 5...17 VDC / 20 mA |
Temperature coefficient | < ±0.01% of span / °C |
Linearity error | < 0.1% of span |
EMC immunity influence | < ±0.5% |
Input specifications
Common input specifications |
|
Max. offset | 90% of selected max. frequency |
Measurement range | 0...20 kHz |
Min. measurement range | 0.001 Hz |
Low cut-off frequency | 0.001 Hz |
Max. frequency, with input filter ON | 50 Hz |
Min. period time with input filter ON | 20 ms |
Input types |
NAMUR acc. to DIN 19234
Tacho NPN / PNP TTL S0 acc. to DIN 43864 |
Output specifications
Common output specifications |
|
Updating time |
40 ms for concurrent f/I and f/f
20 ms |
Current output |
|
Signal range | 0...20 mA |
Min. signal range | 5 mA |
Load (@ current output) | ≤ 600 Ω |
Load stability | ≤ 0.01% of span / 100 Ω |
Current limit | < 23 mA |
Voltage output |
|
Signal range | 0...10 VDC |
Min. signal range | 250 mV |
Load (@ voltage output) | ≥ 500 kΩ |
Relay output |
|
Max. switching frequency | 20 Hz |
Isolation, test / working | 3.75 kVAC / 250 VAC |
Max. voltage | 250 VRMS |
Max. current | 2 AAC |
Max. AC power | 500 VA |
Max. load at 24 VDC | 1 A |
Other output types |
Active outputs (NPN / PNP)
f/f converter output Frequency generator |
of span | = of the presently selected range |
Observed authority requirements
EMC | 2014/30/EU |
LVD | 2014/35/EU |
RoHS | 2011/65/EU |
EAC | TR-CU 020/2011 |