2-wire programmable transmitter
5334B
- TC input
- High measurement accuracy
- Galvanic isolation
- Programmable sensor error value
- For DIN form B sensor head mounting
Application
- Linearized temperature measurement with TC sensor.
- Amplification of bipolar mV signals to a 4...20 mA signal, optionally linearized according to a defined linearization function.
Technical characteristics
- Within a few seconds the user can program PR5334B to measure temperatures within all TC ranges defined by the norms.
- Cold junction compensation (CJC) with a built-in temperature sensor.
- Continuous check of vital stored data for safety reasons.
Mounting / installation
- For DIN form B sensor head mounting.
Data sheet & Manuals
Data sheet
- 5334B.pdf
- Latest version
Manuals
- 5334V115_UK.pdf
- 5334V114_UK.pdf
- 5334V113_UK.pdf
- 5334V112_UK.pdf
- 5334V111_UK.pdf
- 5334V110_UK.pdf
- 5334V109_UK.pdf
- 5334V108_UK.pdf
- 5334V107_UK.pdf
- 5334V106.pdf
- 5334V105.pdf
- 5334V103.pdf
- Previous versions
- Latest version
Manuals in Russian
- 5334V115_RU.pdf
- 5334V114_RU.pdf
- 5334V113_RU.pdf
- 5334V112_RU.pdf
- 5334V111_RU.pdf
- 5334V110_RU.pdf
- 5334V109_RU.pdf
- 5334V108_RU.pdf
- 5334V107_RU.pdf
- 5334L106_RU.pdf
- Previous versions
- Latest version
Manuals in Portuguese (Brazil)
- 5334V115_BR.pdf
- 5334V114_BR.pdf
- 5334V113_BR.pdf
- 5334V112_BR.pdf
- 5334V111_BR.pdf
- 5334V110_BR.pdf
- 5334V109_BR.pdf
- 5334V108_BR.pdf
- Previous versions
- Latest version
Approvals & Certificates
ATEX certificate
- 5334BD_20ATEX0095X_issue0.pdf
- 5334B_06ATEX0062X_issue04.pdf
- 5334B_06ATEX0062X_issue03.pdf
- 5334B_06ATEX0062_issue02.pdf
- Previous versions
- Latest version
IECEx certificate
- 5334BIEC_200059X_issue0.pdf
- 5334BIEC_130035X_issue1.pdf
- 5334BIEC_130035X_issue0.pdf
- Previous versions
- Latest version
INMETRO certificate
- INMETRO_5331_5332_5334_6331_6334_230009X_issue0.pdf
- INMETRO_5331_5332_5334_160013X_issue1.pdf
- INMETRO_5331_5334_160013X_issue0.pdf
- Previous versions
- Latest version
DNV marine certificate
- DNV_2231_41xx_51xx_53xx.pdf
- Latest version
EAC declaration
- EAC_EMC_declaration_Ex_3000_5000_6000_9000.pdf
- Latest version
EAC Ex certificate
- EAC_Ex.pdf
- Latest version
Metrology Pattern Approval (MPA), Belarus
- MPA_Belarus.pdf
- Latest version
Metrology Pattern Approval (MPA), Kazakhstan
- MPA_Kazakhstan.pdf
- Latest version
Metrology Pattern Approval (MPA), Russia
- MPA_Russia.pdf
- Latest version
Supplementary documentation
EU Declaration of Conformity
- 5334DoC_EU_106_UK.pdf
- 5334DoC_EU_105_UK.pdf
- 5334DoC_EU_104_UK.pdf
- 5334DoC_EU_103_UK.pdf
- 5334DoC_EU_102_UK.pdf
- 5334DoC_EU_101_UK.pdf
- 5334DoC_EU_100_UK.pdf
- Previous versions
- Latest version
UKCA Declaration of Conformity
- 5334DoC_UKCA_100_UK.pdf
- Latest version
CCC statement
- 5000_6000_series_CCC_statement.pdf
- Latest version
PR default configurations
- PR_default_configurations.pdf
- Latest version
Safety note
Safety note
Order form
Environmental Conditions
Operating temperature | -40°C to +85°C |
Calibration temperature | 20...28°C |
Relative humidity | < 95% RH (non-cond.) |
Protection degree (encl./terminal) | IP68 / IP00 |
Mechanical specifications
Dimensions | Ø 44 x 20.2 mm |
Weight approx. | 50 g |
Wire size | 1 x 1.5 mm2 stranded wire |
Screw terminal torque | 0.4 Nm |
Vibration | IEC 60068-2-6 |
2...25 Hz | ±1.6 mm |
25...100 Hz | ±4 g |
Common specifications
Supply |
|
Supply voltage | 7.2...30 VDC |
Internal power dissipation | 25 mW…0.8 W |
Isolation voltage |
|
Isolation voltage, test / working | 1.5 kVAC / 50 VAC |
Response time |
|
Response time (programmable) | 1...60 s |
Voltage drop | 7.2 VDC |
Warm-up time | 5 min. |
Power on to stable output | 4.5 s |
Programming | Loop Link |
Signal / noise ratio | Min. 60 dB |
EEprom error check | < 3.5 s |
Accuracy | Better than 0.05% of selected range |
Signal dynamics, input | 18 bit |
Signal dynamics, output | 16 bit |
Effect of supply voltage change | < 0.005% of span / VDC |
EMC immunity influence | < ±0.5% of span |
Extended EMC immunity: NAMUR NE21, A criterion, burst | < ±1% of span |
Input specifications
Common input specifications |
|
Max. offset | 50% of selected max. value |
TC input |
|
Thermocouple type | B, E, J, K, L, N, R, S, T, U, W3, W5, LR |
Cold junction compensation (CJC) | < ±1.0°C |
Sensor error detection | Yes |
Sensor error current: When detecting / else | Nom. 33 μA / 0 μA |
Voltage input |
|
Measurement range | -12...150 mV |
Min. measurement range (span) | 5 mV |
Input resistance | 10 MΩ |
Output specifications
Current output |
|
Signal range | 4…20 mA |
Min. signal range | 16 mA |
Load (@ current output) | ≤ (Vsupply - 7.2) / 0.023 [Ω] |
Load stability | ≤ 0.01% of span / 100 Ω |
Sensor error indication | Programmable 3.5…23 mA |
NAMUR NE43 Upscale/Downscale | 23 mA / 3.5 mA |
Common output specifications |
|
Updating time | 440 ms |
of span | = of the presently selected range |
I.S. / Ex marking
ATEX | II 1 G Ex ia IIC T6...T4 Ga, II 2 D Ex ia IIIC Db, I M1 Ex ia I Ma |
IECEx | Ex ia IIC T6...T4 Ga, Ex ia IIIC Db, Ex ia I Ma |
INMETRO | Ex ia IIC T6...T4 Ga, Ex ia IIIC Db, Ex ia I Ma |
Observed authority requirements
EMC | 2014/30/EU & UK SI 2016/1091 |
ATEX | 2014/34/EU & UK SI 2016/1107 |
RoHS | 2011/65/EU & UK SI 2012/3032 |
EAC | TR-CU 020/2011 |
EAC Ex | TR-CU 012/2011 |
Approvals
ATEX | DEKRA 20ATEX0095X |
IECEx | DEK 20.0059X |
INMETRO | DEKRA 23.0009X |
EAC Ex | EAEU KZ 7500361.01.01.08756 |
DNV Marine | TAA0000101 |
Need support to select the right product for your application?
Our sales engineers are ready to help specify the right device to meet your needs.
Reach out by phone to get in touch with us straight away – or use the contact form or quick quote function to send your RFQ directly from the website. You’ll get a response within 24 hours on normal business days.
You can expect to get a confirmed delivery date via email within 2 days after we have received your order.
As soon as your package leaves our warehouse, you’ll receive tracking details via email. And if you have any questions along the way we’re just a phone call or email away.
State-of-the-art manufacturing Our 8,500 sqm integrated and automated manufacturing campus in Denmark covers the entire value-chain from design and development to manufacturing. It allows us to design and optimize for testing and manufacturing thereby constantly driving quality up and costs down. |
Dedicated Presale / Aftersales
|
Product reliability |
Product deployment
|
Smart products
Check out our range of communication interfaces
|