2-wire level transmitter
5343A
- Potentiometer or Ohmic input
- Programmable sensor error value
- High measurement accuracy
- Unique process calibration function
- Programmable via standard PC
Application
- Conversion of resistance variation to standard analog current signals, e.g. from Ohmic level sensors or valve positions.
- User-defined linearization function can be activated.
Technical characteristics
- Within a few seconds the user can program PR5343A to measure within the defined Ohmic values.
- Continuous check of vital stored data for safety reasons.
- The transmitter is protected against polarity reversal.
- PR5343A is configured to the current task by way of a PC, the PReset software and the communications interface Loop Link.
- The PRelevel configuration tool included in the PReset software has been developed specifically for the configuration of level applications. Among other things, it contains a function for ”on line” measurement of input span as well as a linearization function for volume linear output from horizontal cylindrical tanks.
Mounting / installation
- For DIN form B sensor head or DIN rail mounting with a special fitting.
Ficha técnica y manuales
Ficha técnica
- 5343A.pdf
- Última versión
Manuales
- 5343V111_UK.pdf
- 5343V110_UK.pdf
- 5343V109_UK.pdf
- 5343V108_UK.pdf
- 5343V107_UK.pdf
- 5343V106_UK.pdf
- 5343V105_UK.pdf
- 5343V104_UK.pdf
- 5343V103.pdf
- 5343V102.pdf
- 5343V101.pdf
- Versiones anteriores
- Última versión
Manuales en ruso
- 5343V111_RU.pdf
- 5343V110_RU.pdf
- 5343V109_RU.pdf
- 5343V108_RU.pdf
- 5343V107_RU.pdf
- 5343V106_RU.pdf
- 5343V105_RU.pdf
- 5343V104_RU.pdf
- 5343V103_RU.pdf
- 5343V102_RU.pdf
- Versiones anteriores
- Última versión
Manuales en portugués (Brasil)
- 5343V111_BR.pdf
- 5343V110_BR.pdf
- 5343V109_BR.pdf
- 5343V108_BR.pdf
- 5343V107_BR.pdf
- 5343V106_BR.pdf
- 5343V105_BR.pdf
- 5343V104_BR.pdf
- Versiones anteriores
- Última versión
Homologaciones y certificados
Certificado ATEX
- 5343A_20ATEX0106X_issue0.pdf
- 5343A_10ATEX0004X_issue03.pdf
- 5343A_10ATEX0004X_issue02.pdf
- 5343A_10ATEX0004X_issue01.pdf
- Versiones anteriores
- Última versión
Certificado IECEx
- 5343AIEC_200062X_issue00.pdf
- 5343AIEC_130036X_issue01.pdf
- 5343AIEC_130036X_issue00.pdf
- Versiones anteriores
- Última versión
Certificado INMETRO
- INMETRO_5333_5343_6333_230010X_issue0.pdf
- INMETRO_5333_5343_160014X_issue1.pdf
- INMETRO_5333_5343_160014X_issue0.pdf
- INMETRO_5333_5343_130002X.pdf
- Versiones anteriores
- Última versión
DNV-GL marine certificate
- DNV_2231_41xx_51xx_53xx.pdf
- Última versión
Declaración EAC
- EAC_EMC_declaration_Ex_3000_5000_6000_9000.pdf
- Última versión
Certificado EAC
- EAC_Ex.pdf
- Última versión
Metrology Pattern Approval (MPA), Belarus
- MPA_Belarus.pdf
- Última versión
Metrology Pattern Approval (MPA), Kazakhstan
- MPA_Kazakhstan.pdf
- Última versión
Metrology Pattern Approval (MPA), Russia
- MPA_Russia.pdf
- Última versión
Documentación complementaria
Declaración UE de conformidad
- 5343DoC_EU_106_UK.pdf
- 5343DoC_EU_105_UK.pdf
- 5343DoC_EU_104_UK.pdf
- 5343DoC_EU_103_UK.pdf
- 5343DoC_EU_102_UK.pdf
- 5343DoC_EU_101_UK.pdf
- 5343DoC_EU_100_UK.pdf
- Versiones anteriores
- Última versión
Declaración UKCA de conformidad
- 5343DoC_UKCA_100_UK.pdf
- Última versión
Declaración CCC
- 5000_6000_series_CCC_statement.pdf
- Última versión
Configuraciones por defecto
- PR_default_configurations.pdf
- Última versión
Nota de seguridad
Nota de seguridad
Formulario de pedido
Environmental Conditions
Operating temperature | -40°C to +85°C |
Calibration temperature | 20...28°C |
Relative humidity | < 95% RH (non-cond.) |
Protection degree (encl./terminal) | IP68 / IP00 |
Mechanical specifications
Dimensions | Ø 44 x 20.2 mm |
Weight approx. | 50 g |
Wire size | 1 x 1.5 mm2 stranded wire |
Screw terminal torque | 0.4 Nm |
Vibration | IEC 60068-2-6 |
2...25 Hz | ±1.6 mm |
25...100 Hz | ±4 g |
Common specifications
Supply |
|
Supply voltage | 8.0...35 VDC |
Internal power dissipation | 25 mW…0.8 W |
Response time |
|
Response time (programmable) | 0.33...60 s |
Voltage drop | 8.0 VDC |
Warm-up time | 5 min. |
Programming | Loop Link |
Signal / noise ratio | > 60 dB |
Accuracy | Better than 0.1% of sel. range |
Signal dynamics, input | 19 bit |
Signal dynamics, output | 16 bit |
Effect of supply voltage change | < 0.005% of span / VDC |
EMC immunity influence | < ±0.5% of span |
Input specifications
Common input specifications |
|
Max. offset | 50% of selected max. value |
Linear resistance input |
|
Measurement range / min. range (span) | 0...100 kΩ / 1 kΩ |
Cable resistance per wire (max.) | 100 Ω |
Sensor current | > 25 μA, < 120 μA |
Effect of sensor cable resistance (3-wire) | < 0.002 Ω / Ω |
Sensor error detection | Yes |
Min. measurement range | 1 kΩ |
Output specifications
Current output |
|
Signal range | 4…20 mA |
Min. signal range | 16 mA |
Load (@ current output) | ≤ (Vsupply - 8) / 0.023 [Ω] |
Load stability | ≤ 0.01% of span / 100 Ω |
Sensor error indication | Programmable 3.5…23 mA |
NAMUR NE43 Upscale/Downscale | 23 mA / 3.5 mA |
Common output specifications |
|
Updating time | 135 ms |
of span | = of the presently selected range |
I.S. / Ex marking
ATEX | II 3 G Ex nA [ic] IIC T6...T4 Gc, II 3 G Ex ec [ic] IIC T6...T4 Gc, II 3 G Ex ic IIC T6...T4 Gc, II 3 D Ex ic IIIC Dc |
IECEx | Ex nA [ic] IIC T6…T4 Gc, Ex ec [ic] IIC T6…T4 Gc, Ex ic IIC T6…T4 Gc, Ex ic IIIC Dc |
INMETRO | Ex ec [ic] IIC T6...T4 Gc, Ex ic IIC T6...T4 Gc, Ex ic IIIC Dc |
Observed authority requirements
EMC | 2014/30/EU & UK SI 2016/1091 |
ATEX | 2014/34/EU & UK SI 2016/1107 |
RoHS | 2011/65/EU & UK SI 2012/3032 |
EAC | TR-CU 020/2011 |
EAC Ex | TR-CU 012/2011 |
Approvals
ATEX | DEKRA 20ATEX0106X |
IECEx | DEK 20.0062X |
INMETRO | DEKRA 23.0010X |
EAC Ex | EAEU KZ 7500361.01.01.08756 |
DNV Marine | TAA0000101 |
Need support to select the right product for your application?
Our sales engineers are ready to help specify the right device to meet your needs.
Reach out by phone to get in touch with us straight away – or use the contact form or quick quote function to send your RFQ directly from the website. You’ll get a response within 24 hours on normal business days.
You can expect to get a confirmed delivery date via email within 2 days after we have received your order.
As soon as your package leaves our warehouse, you’ll receive tracking details via email. And if you have any questions along the way we’re just a phone call or email away.
State-of-the-art manufacturing Our 8,500 sqm integrated and automated manufacturing campus in Denmark covers the entire value-chain from design and development to manufacturing. It allows us to design and optimize for testing and manufacturing thereby constantly driving quality up and costs down. |
Dedicated Presale / Aftersales
|
Product reliability |
Product deployment
|
Smart products
Check out our range of communication interfaces
|