Programmable transmitter

 

5114A

 

  • Input for RTD, TC, mV, linear resistance, mA, and V
  • 3-port 3.75 kVAC galvanic isolation
  • Current and voltage output
  • Universal voltage supply
  • 1- and 2-channel versions
  • Loop supply > 17.1 V
DNV Mpa EAC CE Pr Rohs3 Guarantee
  1. Panoramica + -

  2. Dati tecnici + -

  3. Accessori + -

  4. Ordine e consegna + -

  5. Perchè scegliere PR + -

Advanced features

  • The 5114 transmitter can be configured using the PReset software and the Loop Link communications unit.

Application

  • Jumper selectable inputs for current/voltage or temperature.
  • Programmable current (0...100 mA) and voltage (0...250 VDC) inputs.
  • Linearized, electronic temperature measurement.
  • Conversion of linear resistance variation e.g, from solenoids and butterfly valves or linear movements with attached potentiometer.
  • 17.1 VDC loop and 2.5 VDC potentiometer supplies.
  • Automatic 4- / 3-wire or programmable 2-wire cable compensation.
  • Configurable sensor error detection including NAMUR NE43.

Technical characteristics

  • Active or Passive current output and selectable voltage output.
  • Separation of circuits in PELV/SELV installations.

Scheda tecnica & manuali


Scheda tecnica

Manuali

Manuali in russo

Documentazione supplementare


Dichiarazione UE di conformità

Configurazioni predefinite

Approvazioni & certificati


Certificato marina DNV

Dichiarazione EAC

Dichiarazione LVD EAC

Metrology Pattern Approval (MPA), Russia


Metrology Pattern Approval (MPA), Russia

Environmental Conditions

Operating temperature -20°C to +60°C
Calibration temperature 20...28°C
Relative humidity < 95% RH (non-cond.)
Protection degree IP20

Mechanical specifications

Dimensions (HxWxD) 109 x 23.5 x 130 mm
Weight approx. 225 g
DIN rail type DIN EN 60715/35 mm
Wire size 0.13...2.08 mm2 AWG 26...14 stranded wire
Screw terminal torque 0.5 Nm

Common specifications

Supply

Supply voltage, universal 21.6...253 VAC, 50...60 Hz or 19.2...300 VDC
Fuse 400 mA SB / 250 VAC
Max. required power 2.1 W / 2.8 W (1 / 2 ch.)
Max. power dissipation 2.0 W

Isolation voltage

Isolation voltage, test / working 3.75 kVAC / 250 VAC
PELV/SELV IEC 61140

Response time

Temperature input, programmable (0...90%, 100...10%) 400 ms...60 s
mA / V input (programmable) 250 ms...60 s

Auxiliary supplies

2-wire supply (pin 44...42 and 54...52) 28...17.1 VDC / 0...20 mA
Programming Loop Link
Signal / noise ratio Min. 60 dB (0...100 kHz)
Accuracy Better than 0.05% of selected range
Updating time 115 ms (temperature input) 75 ms (mA / V / mV input)
Signal dynamics, input 22 bit
Signal dynamics, output 16 bit
Auxiliary voltages: Reference voltage 2.5 VDC ±0.5% / 15 mA
EMC immunity influence < ±0.5% of span
Extended EMC immunity: NAMUR NE21, A criterion, burst < ±1% of span

Input specifications

Common input specifications

Max. offset 50% of selected max. value

RTD input

RTD type Pt100, Ni100, lin. R
Cable resistance per wire 10 Ω (max.)
Sensor current Nom. 0.2 mA
Effect of sensor cable resistance (3-/4-wire) < 0.002 Ω / Ω
Sensor error detection Yes

TC input

Thermocouple type B, E, J, K, L, N, R, S, T, U, W3, W5, LR
Cold junction compensation (CJC) < ±1.0°C
Sensor error current Nom. 30 μA
Sensor error detection Yes

Current input

Measurement range 0...100 mA
Min. measurement range (span) 4 mA
Input resistance: Supplied unit Nom. 10 Ω + PTC 10 Ω
Input resistance: Non-supplied unit RSHUNT = ∞, VDROP < 6 V

Voltage input

Measurement range 0...250 VDC -150...+150 mV
Min. measurement range (span) 5 mV
Input resistance Nom. 10 MΩ (≤ 2.5 VDC) Nom. 5 MΩ (> 2.5 VDC)
Nom. 10 MΩ (mV input)

Output specifications

Current output

Signal range 0...20 mA
Min. signal range 10 mA
Load (@ current output) ≤ 600 Ω
Load stability ≤ 0.01% of span / 100 Ω
Current limit ≤ 28 mA
Sensor error indication Programmable 0...23 mA
NAMUR NE43 Upscale/Downscale 23 mA / 3.5 mA

Passive 2-wire mA output

Signal range 4...20 mA
Load stability ≤ 0.01% of span / 100 Ω
Max. external 2-wire supply 29 VDC
Effect of external 2-wire supply voltage variation < 0.005% of span / V

Voltage output

Signal range 0...10 VDC
Min. signal range 500 mV
Load (@ voltage output) ≥ 500 kΩ
of span = of the presently selected range

Observed authority requirements

EMC 2014/30/EU
LVD 2014/35/EU
RoHS 2011/65/EU
EAC TR-CU 020/2011
EAC LVD TR-CU 004/2011

Approvals

DNV Marine TAA0000101

 

Need support to select the right product for your application?

Our sales engineers are ready to help specify the right device to meet your needs.

 

Reach out by phone to get in touch with us straight away – or use the contact form or quick quote function to send your RFQ directly from the website. You’ll get a response within 24 hours on normal business days.

 

You can expect to get a confirmed delivery date via email within 2 days after we have received your order.

 

As soon as your package leaves our warehouse, you’ll receive tracking details via email. And if you have any questions along the way we’re just a phone call or email away.

 

State-of-the-art manufacturing

State-of-the-art manufacturing

Our 8,500 sqm integrated and automated manufacturing campus in Denmark covers the entire value-chain from design and development to manufacturing. It allows us to design and optimize for testing and manufacturing thereby constantly driving quality up and costs down.

 

Dedicated Presales / Aftersales

Dedicated Presale / Aftersales
Our more than 80 dedicated sales engineers can help specify the right device for your application. Backed by our 9 subsidiaries and more than 40 dedicated partners, we are directly accessible in more than 40 countries around the world.

 

Find a PR location close to you

 

Product reliability

Product reliability
Although we’d always like to be top of mind, we recognize our job is mainly to provide peace of mind. Install & Forget® is our way of saying that once installed, our devices will continue to perform even in the toughest environments. And we are not afraid to back that statement up with commitments.

 

Product deployment

Product deployment
Our devices are intuitive and simple to configure. Once installed they visualize rich diagnostics data, allowing the operator to plan preventative maintenance, maximizing process up-time.

 

 

Smart products

Smart products
Many of our devices are designed to accommodate current and future communication enablers, providing the operator with multifunctional capabilities that extends into the future.

 

Check out our range of communication interfaces

 

Smart products

 

La vostra richiesta è stata inviata con successo 0 prodotti nella tua lista
I vostri contatti

Informazioni sull'azienda

Inserisci il nome della tua azienda
Inserisci il tuo indirizzo aziendale
Inserisci un Cap valido
Inserisci la città
Selezionare il paese

La tua informazione

Inserisci il tuo nome
Inserisci il tuo cognome
Inserisci un indirizzo di posta elettronica valido
Inserisci un numero di telefono valido. Usa solo numeri.
Inserisci la posizione lavorativa
Leggi e accetta la politica sulla Privacy di PR electronics.
Riceverai una risposta entro 24 ore
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.

A mistake has occurred. Please call us instead

Non hai aggiunto alcun prodotto al tuo elenco di preventivi
Durante la visita del nostro sito Web, sarà possibile aggiungere prodotti a un elenco di preventivi semplicemente facendo clic su "Aggiungi all'elenco dei preventivi" nelle singole pagine dei prodotti. Una volta inclusi tutti i prodotti pertinenti, inviaci l'elenco e otterrai un preventivo entro 24 ore. Se non invii l'elenco, sarà accessibile sul sito Web per 21 giorni. Speriamo che troverai utile la funzionalità.
Grazie per aver richiesto un preventivo. Ti risponderemo telefonicamente o via e-mail entro 24 ore.
Contattaci

Se hai bisogno di assistenza, contattaci sarai sempre il benvenuto

Contattaci
Newsletter Icon Red

Registrati qui per ricevere la nostra newsletter

Newsletter Icon Red