5105B

 

Ex UL List DNV Eac Ex Mpa EAC CE Pr Rohs3 Guarantee
  1. Overview + -

  2. Technical details + -

Data sheet & Manuals


Data sheet

Manuals

Manuals in Russian

Approvals & Certificates


ATEX certificate

UL certificate

DNV marine certificate

EAC declaration

EAC Ex certificate

Metrology Pattern Approval (MPA), Russia

Supplementary documentation


EU Declaration of Conformity

PR default configurations

Safety note

Environmental Conditions

Operating temperature -20°C to +60°C
Calibration temperature 20...28°C
Relative humidity < 95% RH (non-cond.)
Protection degree IP20

Mechanical specifications

Dimensions (HxWxD) 109 x 23.5 x 130 mm
Weight approx. 225 g
DIN rail type DIN 46277
Wire size 1 x 2.5 mm2 stranded wire
Screw terminal torque 0.5 Nm
Vibration IEC 60068-2-6
2...13.2 Hz ±1 mm
13.2...100 Hz ±0.7 g

Common specifications

Supply

Supply voltage, universal 21.6...253 VAC, 50...60 Hz or 19.2...300 VDC
Fuse 400 mA SB / 250 VAC
Max. required power ≤ 2 W (2 channels)
Internal power dissipation ≤ 2 W (2 channels)

Isolation voltage

Isolation voltage, test / working 3.75 kVAC / 250 VAC
PELV/SELV IEC 61140

Response time

Response time (0...90%, 100...10%) < 25 ms
Signal / noise ratio Min. 60 dB (0...100 kHz)
Accuracy Better than 0.1% of sel. range
EMC immunity influence < ±0.5% of span
Extended EMC immunity: NAMUR NE21, A criterion, burst < ±1% of span

Input specifications

Common input specifications

Max. offset 20% of max. value

Current input

Measurement range 0...20 mA
Min. measurement range (span) 16 mA
Input resistance Nom. 10 Ω + PTC 10 Ω

Voltage input

Measurement range 0...10 VDC
Min. measurement range (span) 8 VDC
Input resistance > 2 MΩ

Output specifications

Current output

Signal range 0...20 mA
Min. signal range 16 mA
Load (@ current output) ≤ 770 Ω
Load stability ≤ 0.01% of span / 100 Ω
Current limit ≤ 28 mA

Voltage output

Signal range 0...1 VDC / 0...10 VDC
Min. signal range 0.8 VDC / 8 VDC
Load (@ voltage output) ≥ 500 kΩ
of span = of the presently selected range

Observed authority requirements

EMC 2014/30/EU
LVD 2014/35/EU
EAC TR-CU 020/2011

Approvals

ATEX DEMKO 99ATEX126014, II (1) GD [EEx ia] IIC
c UL us, UL 913 E233311
EAC Ex RU C-DK.HA65.B.00355/19
DNV Marine TAA0000101
Your request has been sent successfully. 0 items on your list
Your contact information

Company information

Please insert your company name.
Please insert your company address
Please insert a valid zip code
Please insert a city
Please select country

Your information

Please insert your last name
Please insert your last name
Please insert a valid email address
Please insert a valid phone number. Use only numbers.
Please insert your job title
Please read and agree with PR electronics’ Privacy Policy.
Get an answer within 24 hours

A mistake has occurred. Please call us instead

You have not added any products to your quote list
When browsing the website, you can add products to a quote list by simply clicking “Add to quote list" on the individual product pages. Once all relevant products are included, send the list to us and you will get a quotation within 24 hours. If you don't submit the list, it will be accessible on the website for 21 days. We hope you will find the functionality useful.
Thank you for requesting a quotation. We will get back to you by phone or email within 24 hours.
Service Red

If you need support, you are always welcome to contact us

Service Red
Newsletter Icon Red

Register here to receive our newsletter

Newsletter Icon Red