Power control unit
9410
- Distributes supply voltage to the power rail
- Optional connection of backup supply
- Approved for installation in I.S. / Ex zone 2 / Div. 2
- Optional redundant supply for the power rail
- Must be installed on power rail, PR type 9400
Application and advanced features
- The power control unit detects errors from any of the devices mounted on the power rail and transmits a collective alarm to the control system via the internal status relay.
- Optional connection of two power supplies - a primary supply and a backup supply.
- Redundant supply for the power rail can be obtained by mounting two 9410 devices connected to 2 separate power supplies (e.g. PR no. 9421).
Technical characteristics
- The status relay will be energised when the following three conditions are met:
1. Supply voltage is present on pins 31 and 32.
2. Backup supply voltage is present on pins 34 and 33. (If the backup supply is not in use, a jumper must be placed between pins 32 and 33 - the jumper is delivered with the device).
3. There are no error messages from the devices connected to the power rail. - When a collective alarm is activated via the power rail, the status relay in the 9410 will be de-energized (pins 11, 12 and 13).
- Two green front LEDs indicate connection of supply and backup.
- A red LED indicates error status.
Data sheet & Manuals
Data sheet
- 9410.pdf
- Latest version
Manuals
- 9410V001_108_UK.pdf
- 9410V001_107_UK.pdf
- 9410V001_106_UK.pdf
- 9410V001_105_UK.pdf
- 9410V001_104_UK.pdf
- 9410V001_103_UK.pdf
- 9410V001_102_UK.pdf
- 9410V001_101_UK.pdf
- 9410V001_100_UK.pdf
- Previous versions
- Latest version
Manuals in Russian
- 9410V001_108_RU.pdf
- 9410V001_107_RU.pdf
- 9410V001_106_RU.pdf
- 9410V001_105_RU.pdf
- 9410V001_104_RU.pdf
- 9410V001_103_RU.pdf
- 9410V001_102_RU.pdf
- 9410V001_101_RU.pdf
- Previous versions
- Latest version
Manuals in Portuguese (Brazil)
- 9410V001_108_BR.pdf
- 9410V001_107_BR.pdf
- 9410V001_106_BR.pdf
- 9410V001_105_BR.pdf
- 9410V001_104_BR.pdf
- 9410V001_103_BR.pdf
- 9410V001_102_BR.pdf
- 9410V001_101_BR.pdf
- Previous versions
- Latest version
Manuals in Korean
- 9410V001_108_KR.pdf
- 9410V001_107_KR.pdf
- 9410V001_106_KR.pdf
- Previous versions
- Latest version
Approvals & Certificates
ATEX certificate
- 9410B_07ATEX0152X_issue3.pdf
- 9410B_07ATEX0152X_issue2.pdf
- 9410B_07ATEX0152X_issue1.pdf
- Previous versions
- Latest version
IECEx certificate
- 9410IEC_080025X_issue5.pdf
- 9410IEC_080025X_issue4.pdf
- 9410IEC_080025X_issue3.pdf
- 9410IEC_080025X_issue2.pdf
- 9410IEC_080025X_issue1.pdf
- 9410IEC_080025X_issue0.pdf
- Previous versions
- Latest version
UKEX certificate
- 9410_21UKEX0169X_issue0.pdf
- Latest version
CCC certificate
- 9410_CCC_2023_04.pdf
- 9410_CCC_2020_11.pdf
- Previous versions
- Latest version
FM certificate
- 9410_FM_19US0056X_FM19CA0029X.pdf
- Latest version
INMETRO certificate
- 9410_INMETRO_230013X_issue0.pdf
- 9410_INMETRO_160007X_issue2.pdf
- 9410_INMETRO_160007X_issue1.pdf
- 9410_INMETRO_160007X_issue0.pdf
- Previous versions
- Latest version
KCs certificate
- 9410_KCs_21_AV4BO_0185.pdf
- Latest version
UL certificate
DNV marine certificate
- DNV_9xxx_4510_4511.pdf
- Latest version
EAC declaration
- EAC_EMC_declaration_Ex_3000_5000_6000_9000.pdf
- Latest version
EAC LVD declaration
- EAC_LVD-Declaration.pdf
- Latest version
EAC Ex certificate
- EAC_Ex.pdf
- Latest version
Metrology Pattern Approval (MPA), Russia
- MPA_Russia.pdf
- Latest version
Supplementary documentation
EU Declaration of Conformity
- 9410DoC_EU_104_UK.pdf
- 9410DoC_EU_103_UK.pdf
- 9410DoC_EU_102_UK.pdf
- 9410DoC_EU_101_UK.pdf
- 9410DoC_EU_100_UK.pdf
- Previous versions
- Latest version
UKCA Declaration of Conformity
- 9410DoC_UKCA_100.pdf
- Latest version
EMC data
- 9000_EMC_data.pdf
- Latest version
Safety note
Safety note
- SN9410_113_2418.pdf
- SN9410_112_2306.pdf
- SN9410_111_2049.pdf
- SN9410_110_2033.pdf
- SN9410_109_2007.pdf
- SN9410_108_1907.pdf
- SN9410_9420_106_1615.pdf
- SN9000_104_1344.pdf
- Previous versions
- Latest version
Order form
Environmental Conditions
Operating temperature | -20°C to +60°C |
Storage temperature | -20°C to +85°C |
Relative humidity | < 95% RH (non-cond.) |
Protection degree | IP20 |
Installation in | Pollution degree 2 & meas. / overvoltage cat. II |
Mechanical specifications
Dimensions (HxWxD) | 109 x 23.5 x 104 mm |
Weight approx. | 140 g |
DIN rail type | DIN EN 60715/35 mm |
Wire size | 0.13...2.08 mm2 AWG 26...14 stranded wire |
Screw terminal torque | 0.5 Nm |
Vibration | IEC 60068-2-6 |
2...13.2 Hz | ±1 mm |
13.2...100 Hz | ±0.7 g |
Common specifications
Supply |
|
Max. required power | 96 W |
Internal power dissipation | 2 W (max.) |
Efficiency | > 97.9% |
Input specifications
Supply voltage | 21.6...26.4 VDC (double / reinforced isolation) |
Backup supply | 21.6...26.4 VDC |
Output specifications
Status relay |
|
Max. voltage | 250 / 30 VDC |
Max. current | 2 AAC / 2 ADC |
Max. AC power | 500 VA / 60 W |
Output voltage | Input voltage-0.5 VDC (@ 4 A) |
Output power | 96 W (max.) |
Output current | 4 A (max.) |
Output ripple | Same as input ripple |
Observed authority requirements
EMC | 2014/30/EU & UK SI 2016/1091 |
LVD | 2014/35/EU & UK SI 2016/1101 |
ATEX | 2014/34/EU & UK SI 2016/1107 |
RoHS | 2011/65/EU & UK SI 2012/3032 |
EAC | TR-CU 020/2011 |
EAC Ex | TR-CU 012/2011 |
EAC LVD | TR-CU 004/2011 |
Approvals
ATEX | KEMA 07ATEX0152 X |
IECEx | KEM 08.0025X |
UKEX | DEKRA 21UKEX0169X |
c FM us | FM19US0056X /FM19CA0029X |
INMETRO | DEKRA 23.0013X |
c UL us, UL 61010-1 | E314307 |
c UL us, UL 913 | E233311 (only 9410-U9) |
KCs | 21_AV4BO_0185X (only 9410-KCs) |
CCC | 2020322303003230 |
EAC Ex | RU C-DK.HA65.B.00355/19 |
DNV Marine | TAA00000JD |
Need support to select the right product for your application?
Our sales engineers are ready to help specify the right device to meet your needs.
Reach out by phone to get in touch with us straight away – or use the contact form or quick quote function to send your RFQ directly from the website. You’ll get a response within 24 hours on normal business days.
You can expect to get a confirmed delivery date via email within 2 days after we have received your order.
As soon as your package leaves our warehouse, you’ll receive tracking details via email. And if you have any questions along the way we’re just a phone call or email away.
State-of-the-art manufacturing Our 8,500 sqm integrated and automated manufacturing campus in Denmark covers the entire value-chain from design and development to manufacturing. It allows us to design and optimize for testing and manufacturing thereby constantly driving quality up and costs down. |
Dedicated Presale / Aftersales
|
Product reliability |
Product deployment
|
Smart products
Check out our range of communication interfaces
|