6334B
Data sheet & Manuals
Data sheet
- 6334B.pdf
- Latest version
Manuals
- 6334V108_UK.pdf
- 6334V107_UK.pdf
- 6334V106_UK.pdf
- 6334V105_UK.pdf
- 6334V104.pdf
- 6334V103.pdf
- Previous versions
- Latest version
Manuals in Russian
- 6334V108_RU.pdf
- 6334V107_RU.pdf
- 6334V106_RU.pdf
- 6334L105_RU.pdf
- 6334L104_RU.pdf
- Previous versions
- Latest version
Approvals & Certificates
ATEX certificate
- 6334B_20ATEX0095X_issue0.pdf
- 6334B_06ATEX0115X_issue05.pdf
- 6334B_06ATEX0115X_issue04.pdf
- 6334B_06ATEX0115X_issue03.pdf
- 6334B_06ATEX0115_issue02.pdf
- Previous versions
- Latest version
IECEx certificate
- 6334BIEC_200059x_issue0.pdf
- 6334BIEC_140047X_issue02.pdf
- 6334BIEC_140047X_issue01.pdf
- 6334BIEC_140047X_issue0.pdf
- Previous versions
- Latest version
EAC declaration
- EAC_EMC_declaration_Ex_3000_5000_6000_9000.pdf
- Latest version
EAC Ex certificate
- EAC_Ex.pdf
- Latest version
Metrology Pattern Approval (MPA), Belarus
- MPA_Belarus.pdf
- Latest version
Metrology Pattern Approval (MPA), Kazakhstan
- MPA_Kazakhstan.pdf
- Latest version
Metrology Pattern Approval (MPA), Russia
- MPA_Russia.pdf
- Latest version
Supplementary documentation
EU Declaration of Conformity
- 6334DoC_EU_103_UK.pdf
- 6334DoC_EU_102_UK.pdf
- 6334DoC_EU_101_UK.pdf
- 6334DoC_EU_100_UK.pdf
- Previous versions
- Latest version
UKCA Declaration of Conformity
- 6334DoC_UKCA_100_UK.pdf
- Latest version
CCC statement
- 5000_6000_series_CCC_statement.pdf
- Latest version
PR default configurations
- PR_default_configurations.pdf
- Latest version
Safety note
Safety note
- SN6300-1_108_2311.pdf
- SN6300-1_107_2242.pdf
- SN6300-1_106_2010.pdf
- SN6300-1_105_1749.pdf
- SN6300-1_104_1650.pdf
- SN6300-1_103_1614.pdf
- SN6300_102_1506.pdf
- Previous versions
- Latest version
Environmental Conditions
Operating temperature | -40°C to +85°C |
Storage temperature | -40°C to +85°C |
Calibration temperature | 20...28°C |
Relative humidity | < 95% RH (non-cond.) |
Protection degree | IP20 |
Mechanical specifications
Dimensions (HxWxD) | 109 x 23.5 x 104 mm |
Weight (1 / 2 channels) | 145 / 185 g |
DIN rail type | DIN EN 60715/35 mm |
Wire size | 0.13...2.08 mm2 AWG 26...14 stranded wire |
Screw terminal torque | 0.5 Nm |
Common specifications
Supply |
|
Supply voltage | 7.2...30 VDC |
Max. required power | ≤ 0.7 W/≤ 1.4 W (1 ch./2 ch.) |
Power dissipation, per channel | 0.17...0.7 W |
Isolation voltage |
|
Isolation voltage, test / working | 1.5 kVAC / 50 VAC |
Response time |
|
Response time (programmable) | 1...60 s |
Voltage drop | 7.2 VDC |
Warm-up time | 5 min. |
Programming | Loop Link |
Signal / noise ratio | Min. 60 dB |
Accuracy | Better than 0.05% of selected range |
EEprom error check | < 3.5 s |
Signal dynamics, input | 18 bit |
Signal dynamics, output | 16 bit |
Effect of supply voltage change | < 0.005% of span / VDC |
EMC immunity influence | < ±0.5% of span |
Extended EMC immunity: NAMUR NE21, A criterion, burst | < ±1% of span |
Input specifications
Common input specifications |
|
Max. offset | 50% of selected max. value |
TC input |
|
Thermocouple type | B, E, J, K, L, N, R, S, T, U, W3, W5, LR |
Cold junction compensation (CJC) | < ±1.0°C |
Voltage input |
|
Measurement range | -12...150 mV |
Min. measurement range (span) | 5 mV |
Input resistance | 10 MΩ |
Output specifications
Current output |
|
Signal range | 4…20 mA |
Min. signal range | 16 mA |
Load (@ current output) | ≤ (Vsupply - 7.2) / 0.023 [Ω] |
Sensor error indication | Programmable 3.5…23 mA |
NAMUR NE43 Upscale/Downscale | 23 mA / 3.5 mA |
Common output specifications |
|
Updating time | 440 ms |
of span | = of the presently selected range |
Observed authority requirements
EMC | 2014/30/EU & UK SI 2016/1091 |
ATEX | 2014/34/EU & UK SI 2016/1107 |
RoHS | 2011/65/EU & UK SI 2012/3032 |
EAC | TR-CU 020/2011 |
EAC Ex | TR-CU 012/2011 |
Approvals
ATEX | DEKRA 20ATEX0095X |
IECEx | DEK 20.0059X |
EAC Ex | RU C-DK.HA65.B.00355/19 |