Field mounted HART temperature transmitter
7501
- RTD, TC, Ohm, and bipolar mV input and analog output
- High definition local operator interface (LOI) with 3 optical buttons
- Selectable red or white backlight
- Ex d explosion proof / flame proof in aluminum or 316 stainless steel version
- HART 7 functionality with HART 5 compatibility
High defintion display
- 0, 90, 180, & 270 degree position adjustments.
- Monitoring, programming and diagnostics view.
- Extensive diagnostics with flashing red or white backlight
- Supports 7 languages.
Local operator interface (LOI)
- 3 optical buttons; up, down and enter.
- Dynamically adaptive to wear or accumulation of dirt.
- Immune to interference from ambient light sources.
- Useable with or without gloves.
Configuration
- From the LOI through PR guided menu.
- PReset and HART modem.
- HHC, DCS or AMS via HART.
Mounting / installation
- For installation in zone 0, 1, 2 and zone 21, 22 and in Class 1, Division 1 and 2 applications.
- Hardware assessed for use in SIL applications.
- Mounting on 1.5”–2” pipe bracket or on wall / bulkhead.
Application
- Linearized temperature measurement with TC and RTD sensors e.g. Pt100 and Ni100.
- HART communication and 4...20 mA analog PV output for individual, difference or average temperature measurement of up to two RTD or TC input sensors.
- Conversion of linear resistance to a standard analog current signal, e.g from valves or Ohmic level sensors.
- Amplification of bipolar mV signals to standard 4...20 mA current signals.
- Up to 63 transmitters (HART 7) can be connected in a multidrop communication setup.
Technical characteristics
- NAMUR NE43 and NE89.
- HART protocol revision can be changed by user configuration to either HART 5 or HART 7 protocol.
Data sheet & Manuals
Data sheet
- 7501.pdf
- Latest version
Manuals
- 7501V114_UK.pdf
- 7501V113_UK.pdf
- 7501V112_UK.pdf
- 7501V111_UK.pdf
- 7501V110_UK.pdf
- 7501V109_UK.pdf
- 7501V108_UK.pdf
- 7501V107_UK.pdf
- 7501V106_UK.pdf
- 7501V105_UK.pdf
- 7501V104_UK.pdf
- 7501V103_UK.pdf
- 7501V102_UK.pdf
- 7501V101_UK.pdf
- 7501V100_UK.pdf
- Previous versions
- Latest version
Manuals in Russian
Approvals & Certificates
ATEX certificate
- 7501_issue05.pdf
- 7501_issue04.pdf
- 7501_issue03.pdf
- 7501_issue01.pdf
- Previous versions
- Latest version
IECEx certificate
- 7501IEC_issue04.pdf
- 7501IEC_issue03.pdf
- 7501IEC_issue02.pdf
- 7501IEC_issue01.pdf
- 7501IEC_issue00.pdf
- Previous versions
- Latest version
CSA certificate
- 7501_CSA.pdf
- Latest version
FM certificate
- 7501_FM.pdf
- Latest version
INMETRO certificate
- 7501_INMETRO_230012X_issue0.pdf
- 7501_INMETRO_150014X_issue3.pdf
- 7501_INMETRO_150014X_issue2.pdf
- 7501_INMETRO_150014X_issue1.pdf
- 7501_INMETRO_150014X_issue0.pdf
- Previous versions
- Latest version
NEPSI certificate
- 7501_NEPSI.pdf
- Latest version
SIL declaration
- 5335_6335_5337_6337_7501_SIL1_declaration_Potmeter_V2.pdf
- 5335_6335_5337_6337_7501_SIL2_declaration_V2.pdf
DNV marine certificate
- DNV_7501_MRA0000009_issue1.pdf
- Latest version
EAC declaration
- EAC_EMC_declaration_Ex_3000_5000_6000_9000.pdf
- Latest version
EAC Ex certificate
- EAC_Ex.pdf
- Latest version
Metrology Pattern Approval (MPA), Russia
- MPA_Russia.pdf
- Latest version
Supplementary documentation
EU Declaration of Conformity
- 7501DoC_EU_104_UK.pdf
- 7501DoC_EU_103_UK.pdf
- 7501DoC_EU_102_UK.pdf
- 7501DoC_EU_101_UK.pdf
- 7501DoC_EU_100_UK.pdf
- Previous versions
- Latest version
UKCA Declaration of Conformity
- 7501DoC_UKCA_100_UK.pdf
- Latest version
CCC statement
- 7501_CCC_statement.pdf
- Latest version
FMEDA report
- FMEDA_7501_R026V3R2.pdf
- FMEDA_7501_R026V3R1.pdf
- Previous versions
- Latest version
HART certificate
- 7501_HART_7_Certificate.pdf
- 7501_HART_5_certificate.pdf
- Previous versions
- Latest version
Paint specifications
- 7501_Paint_specifications.pdf
- Latest version
PR default configurations
- PR_default_configurations.pdf
- Latest version
Safety note
Safety note
Download Software
Order form
Environmental Conditions
Operating temperature |
-40°C to +85°C (with silicone O-ring)
-20°C to +85°C (with FKM O-ring) |
Storage temperature | -40°C to +85°C |
Calibration temperature | 20...28°C |
Relative humidity | 0...100% RH (condensing) |
Protection degree | IP54 / IP66 / IP68 / type 4X |
Corrosion class 7501AxxxBxxxx / durability | C5-I/M / 5...15 years |
Mechanical specifications
Dimensions | Ø 110 mm |
Dimensions (HxWxD), aluminum | 109.3 x 145 x 126 mm |
Dimensions (HxWxD), stainless steel | 107.4 x 145 x 124 mm |
Weight approx., aluminum / stainless steel | 1.3 / 2.8 kg |
Wire size | 0.13 x1.5 mm2 / AWG 26...16 stranded wire |
Screw terminal torque | 0.4 Nm |
Vibration | IEC 60068-2-6 |
2...25 Hz | ±1.6 mm |
25...100 Hz | ±4 g |
Display resolution | 96 x 64 pixels |
Number of digits | 5 |
Backlight | Selectable ON/OFF |
Backlight color | Selectable white or red |
Common specifications
Supply |
|
Supply voltage, DC: Ex ia, intrinsically safe | 10 (12 - with backlight)...30 VDC |
Supply voltage, DC: Other | 10 (12 - with backlight)...35 VDC |
Isolation voltage |
|
Isolation voltage, test / working | 1.5 kVAC / 50 VAC |
Response time |
|
Response time (programmable) | 1...60 s |
Signal / noise ratio | > 60 dB |
Programming | HART |
Start-up time, transmitter to display | Max. 5 s |
Long-term stability, better than | ±0.1% of span / year |
Accuracy | Better than 0.05% of selected range |
Signal dynamics, input | 22 bit |
Signal dynamics, output | 16 bit |
EMC immunity influence | < ±0.1% of span |
Extended EMC immunity: NAMUR NE21, A criterion, burst | < ±1% of span |
Input specifications
Common input specifications |
|
Max. offset | 50% of selected max. value |
RTD input |
|
RTD type | Pt50/100/200/500/1000; Ni50/100/120/1000 |
Cable resistance per wire | 5 Ω (up to 50 Ω per wire is possible with reduced measurement accuracy) |
Sensor current | Nom. 0.2 mA |
Linear resistance input |
|
Linear resistance min....max. | 0 Ω...7000 Ω |
TC input |
|
Thermocouple type | B, E, J, K, L, N, R, S, T, U, W3, W5, LR |
Cold junction compensation (CJC) | Constant, internal or external via a Pt100 or Ni100 sensor |
Voltage input |
|
Measurement range | -800...+800 mV |
Min. measurement range (span) | 2.5 mV |
Input resistance | 10 MΩ |
Output specifications
Current output |
|
Signal range | 4…20 mA |
Min. signal range | 16 mA |
Load (@ current output) | ≤ (Vsupply - 10) / 0.023 [Ω] |
Load resistance, with backlight | ≤ (Vsupply - 12) / 0.023 [Ω] |
Sensor error indication | Programmable 3.5…23 mA |
NAMUR NE43 Upscale/Downscale | 23 mA / 3.5 mA |
Common output specifications |
|
Updating time | 440 ms |
HART protocol revisions | HART 7 and HART 5 |
Observed authority requirements
EMC | 2014/30/EU & UK SI 2016/1091 |
ATEX | 2014/34/EU & UK SI 2016/1107 |
RoHS | 2011/65/EU & UK SI 2012/3032 |
EAC | TR-CU 020/2011 |
EAC Ex | TR-CU 012/2011 |
Approvals
ATEX | DEKRA 15ATEX0058X |
IECEx | IECEx DEK 15.0039 X |
c FM us | FM16US0009X / FM16CA0010X |
CSA | 70024231 |
INMETRO | DEKRA 23.0012 X |
NEPSI | GYJ20.1630X |
EU RO MR Type Approval | MRA0000009 |
EAC Ex | EAEU KZ 7500361.01.01.08756 |
SIL | Hardware assessed for use in SIL applications |