2-wire level transmitter
5343B
- Potentiometer or Ohmic input
- Programmable sensor error value
- High measurement accuracy
- Unique process calibration function
- Programmable via standard PC
Application
- Conversion of resistance variation to standard analog current signals, e.g. from Ohmic level sensors or valve positions.
- User-defined linearization function can be activated.
Technical characteristics
- Within a few seconds the user can program PR5343B to measure within the defined Ohmic values.
- Continuous check of vital stored data for safety reasons.
- The transmitter is protected against polarity reversal.
- PR5343B is configured to the current task by way of a PC, the PReset software and the communications interface Loop Link.
- The PRelevel configuration tool included in the PReset software has been developed specifically for the configuration of level applications. Among other things, it contains a function for ”on line” measurement of input span as well as a linearization function for volume linear output from horizontal cylindrical tanks.
Mounting / installation
- For DIN form B sensor head or DIN rail mounting with a special fitting.
Datablad & Manualer
Datablad
- 5343B.pdf
- Senaste versionen
Manualer
- 5343V111_UK.pdf
- 5343V110_UK.pdf
- 5343V109_UK.pdf
- 5343V108_UK.pdf
- 5343V107_UK.pdf
- 5343V106_UK.pdf
- 5343V105_UK.pdf
- 5343V104_UK.pdf
- 5343V103.pdf
- 5343V102.pdf
- 5343V101.pdf
- Tidigare versioner
- Senaste versionen
Manualer på ryska
- 5343V111_RU.pdf
- 5343V110_RU.pdf
- 5343V109_RU.pdf
- 5343V108_RU.pdf
- 5343V107_RU.pdf
- 5343V106_RU.pdf
- 5343V105_RU.pdf
- 5343V104_RU.pdf
- 5343V103_RU.pdf
- 5343V102_RU.pdf
- Tidigare versioner
- Senaste versionen
Manualer på portugisiska (Brasilien)
- 5343V111_BR.pdf
- 5343V110_BR.pdf
- 5343V109_BR.pdf
- 5343V108_BR.pdf
- 5343V107_BR.pdf
- 5343V106_BR.pdf
- 5343V105_BR.pdf
- 5343V104_BR.pdf
- Tidigare versioner
- Senaste versionen
Godkännanden och certifikat
ATEX-certifikat
- 5343B_20ATEX0105_issue0.pdf
- 5343B_03ATEX1538X_issue04.pdf
- 5343B_03ATEX1538X_issue03.pdf
- 5343B_03ATEX1538_issue02.pdf
- Tidigare versioner
- Senaste versionen
IECEx-certifikat
- 5343BIEC_200062X_issue00.pdf
- 5343BIEC_130036X_issue01.pdf
- 5343BIEC_130036X_issue00.pdf
- Tidigare versioner
- Senaste versionen
FM-certifikat
- 53xx_633x_FM17US0013X.pdf
- 53xx_633x_FM_2D5A7.pdf
- Tidigare versioner
- Senaste versionen
INMETRO-certifikat
- INMETRO_5333_5343_6333_230010X_issue0.pdf
- INMETRO_5333_5343_160014X_issue1.pdf
- INMETRO_5333_5343_160014X_issue0.pdf
- INMETRO_5333_5343_130002X.pdf
- Tidigare versioner
- Senaste versionen
DNV-GL marine certificate
- DNV_2231_41xx_51xx_53xx.pdf
- Senaste versionen
EAC-försäkran
- EAC_EMC_declaration_Ex_3000_5000_6000_9000.pdf
- Senaste versionen
EAC Ex-certifikat
- EAC_Ex.pdf
- Senaste versionen
Metrology Pattern Approval (MPA), Belarus
- MPA_Belarus.pdf
- Senaste versionen
Metrology Pattern Approval (MPA), Kazakhstan
- MPA_Kazakhstan.pdf
- Senaste versionen
Metrology Pattern Approval (MPA), Russia
- MPA_Russia.pdf
- Senaste versionen
Kompletterande dokumentation
EU försäkran om överensstämmelse
- 5343DoC_EU_106_UK.pdf
- 5343DoC_EU_105_UK.pdf
- 5343DoC_EU_104_UK.pdf
- 5343DoC_EU_103_UK.pdf
- 5343DoC_EU_102_UK.pdf
- 5343DoC_EU_101_UK.pdf
- 5343DoC_EU_100_UK.pdf
- Tidigare versioner
- Senaste versionen
UKCA försäkran om överensstämmelse
- 5343DoC_UKCA_100_UK.pdf
- Senaste versionen
CCC-uttalande
- 5000_6000_series_CCC_statement.pdf
- Senaste versionen
PR-standardkonfigurationer
- PR_default_configurations.pdf
- Senaste versionen
Säkerhetsanvisningar
Säkerhetsanvisningar
Beställningsformulär
Environmental Conditions
Operating temperature | -40°C to +85°C |
Calibration temperature | 20...28°C |
Relative humidity | < 95% RH (non-cond.) |
Protection degree (encl./terminal) | IP68 / IP00 |
Mechanical specifications
Dimensions | Ø 44 x 20.2 mm |
Weight approx. | 50 g |
Wire size | 1 x 1.5 mm2 stranded wire |
Screw terminal torque | 0.4 Nm |
Vibration | IEC 60068-2-6 |
2...25 Hz | ±1.6 mm |
25...100 Hz | ±4 g |
Common specifications
Supply |
|
Supply voltage | 8.0...30 VDC |
Internal power dissipation | 25 mW…0.7 W |
Response time |
|
Response time (programmable) | 0.33...60 s |
Voltage drop | 8.0 VDC |
Warm-up time | 5 min. |
Programming | Loop Link |
Signal / noise ratio | > 60 dB |
Accuracy | Better than 0.1% of sel. range |
Signal dynamics, input | 19 bit |
Signal dynamics, output | 16 bit |
Effect of supply voltage change | < 0.005% of span / VDC |
EMC immunity influence | < ±0.5% of span |
Input specifications
Common input specifications |
|
Max. offset | 50% of selected max. value |
Linear resistance input |
|
Measurement range / min. range (span) | 0...100 kΩ / 1 kΩ |
Cable resistance per wire (max.) | 100 Ω |
Sensor current | > 25 μA, < 120 μA |
Effect of sensor cable resistance (3-wire) | < 0.002 Ω / Ω |
Sensor error detection | Yes |
Min. measurement range | 1 kΩ |
Output specifications
Current output |
|
Signal range | 4…20 mA |
Min. signal range | 16 mA |
Load (@ current output) | ≤ (Vsupply - 8) / 0.023 [Ω] |
Load stability | ≤ 0.01% of span / 100 Ω |
Sensor error indication | Programmable 3.5…23 mA |
NAMUR NE43 Upscale/Downscale | 23 mA / 3.5 mA |
Common output specifications |
|
Updating time | 135 ms |
of span | = of the presently selected range |
I.S. / Ex marking
ATEX | II 1 G Ex ia IIC T6...T4 Ga, II 2 D Ex ia IIIC Db, I M1 Ex ia I Ma |
IECEx | Ex ia IIC T6...T4 Ga, Ex ia IIIC Db, Ex ia I Ma |
FM, US | Cl. I, Div. 1, Gp. A, B, C, D T4/T6; Cl. I Zone 0, AEx ia IIC T4/T6; Cl. 1, Div. 2, Gp. A, B, C, D, T4/T6 |
INMETRO | Ex ia IIC T6...T4 Ga, Ex ia IIIC Db, Ex ia I Ma |
Observed authority requirements
EMC | 2014/30/EU & UK SI 2016/1091 |
ATEX | 2014/34/EU & UK SI 2016/1107 |
RoHS | 2011/65/EU & UK SI 2012/3032 |
EAC | TR-CU 020/2011 |
EAC Ex | TR-CU 012/2011 |
Approvals
ATEX | DEKRA 20ATEX0105X |
IECEx | DEK 20.0062X |
FM | FM17US0013X |
INMETRO | DEKRA 23.0010X |
EAC Ex | EAEU KZ 7500361.01.01.08756 |
DNV Marine | TAA0000101 |
Need support to select the right product for your application?
Our sales engineers are ready to help specify the right device to meet your needs.
Reach out by phone to get in touch with us straight away – or use the contact form or quick quote function to send your RFQ directly from the website. You’ll get a response within 24 hours on normal business days.
You can expect to get a confirmed delivery date via email within 2 days after we have received your order.
As soon as your package leaves our warehouse, you’ll receive tracking details via email. And if you have any questions along the way we’re just a phone call or email away.
State-of-the-art manufacturing Our 8,500 sqm integrated and automated manufacturing campus in Denmark covers the entire value-chain from design and development to manufacturing. It allows us to design and optimize for testing and manufacturing thereby constantly driving quality up and costs down. |
Dedicated Presale / Aftersales
|
Product reliability |
Product deployment
|
Smart products
Check out our range of communication interfaces
|