9106B
Data sheet & Manuals
Data sheet
- 9106B.pdf
- Latest version
Manuals
- 9106V002_111_UK.pdf
- 9106V002_110_UK.pdf
- 9106V002_109_UK.pdf
- 9106V002_108_UK.pdf
- 9106V002_107_UK.pdf
- 9106V002_106_UK.pdf
- 9106BV002_105_UK.pdf
- 9106BV002_104_UK.pdf
- 9106BV002_103_UK.pdf
- 9106BV002_102_UK.pdf
- 9106BV002_101_UK.pdf
- 9106BV001_100_UK.pdf
- 9106AV002_102_UK.pdf
- 9106AV002_101_UK.pdf
- 9106AV002_100_UK.pdf
- Previous versions
- Latest version
Manuals in Russian
- 9106V002_111_RU.pdf
- 9106V002_110_RU.pdf
- 9106V002_109_RU.pdf
- 9106V002_108_RU.pdf
- 9106V002_107_RU.pdf
- 9106V002_106_RU.pdf
- 9106BV002_105_RU.pdf
- 9106BV002_104_RU.pdf
- 9106BV002_103_RU.pdf
- 9106BV002_102_RU.pdf
- Previous versions
- Latest version
Manuals in Portuguese (Brazil)
- 9106V002_111_BR.pdf
- 9106V002_110_BR.pdf
- 9106V002_109_BR.pdf
- 9106V002_108_BR.pdf
- 9106V002_107_BR.pdf
- 9106V002_106_BR.pdf
- 9106BV002_105_BR.pdf
- 9106BV002_104_BR.pdf
- 9106BV002_103_BR.pdf
- 9106BV002_102_BR.pdf
- Previous versions
- Latest version
Manuals in Korean
- 9106V002_111_KR.pdf
- 9106V002_110_KR.pdf
- 9106V002_109_KR.pdf
- 9106V002_108_KR.pdf
- Previous versions
- Latest version
Safety manual (SIL)
- 9106_Safety_Manual_V2R0.pdf
- Latest version
Approvals & Certificates
ATEX certificate
- 9106B_11ATEX0244X_issue4.pdf
- 9106B_11ATEX0244X_issue3.pdf
- 9106B_11ATEX0244X_issue2.pdf
- 9106B_11ATEX0244X_issue1.pdf
- Previous versions
- Latest version
IECEx certificate
- 9106BIEC_110084X_issue3.pdf
- 9106BIEC_110084X_issue2.pdf
- 9106BIEC_110084X_issue1.pdf
- 9106BIEC_110084X_issue0.pdf
- Previous versions
- Latest version
UKEX certificate
- 9106B_23UKEX0107X_issue0.pdf
- 9106B_21UKEX0171X_issue0.pdf
- Previous versions
- Latest version
FM certificate
- 9106_9107_FM16US0465X_FM16CA0213X.pdf
- 9106_9107_FM.pdf
- Previous versions
- Latest version
INMETRO certificate
- 9106_INMETRO_230003X_issue0.pdf
- 9106_INMETRO_160001X_issue2.pdf
- 9106_INMETRO_160001X_issue1.pdf
- 9106_INMETRO_160001X_issue0.pdf
- Previous versions
- Latest version
SIL certificate
- 9106_002_SIL.pdf
- Latest version
UL certificate
CCC certificate
- 9106_CCC_2023_04.pdf
- 9106_CCC_2020_11.pdf
- Previous versions
- Latest version
KCs certificate
- 9106B_KCs_21_AV4BO_0167X_0168X.pdf
- Latest version
DNV marine certificate
ClassNK certificate
- ClassNK-TA24034M_91xx_92xx_94xx.pdf
- Latest version
EAC declaration
- EAC_EMC_declaration_Ex_3000_5000_6000_9000.pdf
- Latest version
EAC Ex certificate
- EAC_Ex.pdf
- Latest version
Metrology Pattern Approval (MPA), Russia
- MPA_Russia.pdf
- Latest version
Supplementary documentation
EU Declaration of Conformity
- 9106DoC_EU_104_UK.pdf
- 9106DoC_EU_103_UK.pdf
- 9106DoC_EU_102_UK.pdf
- 9106DoC_EU_101_UK.pdf
- 9106DoC_EU_100_UK.pdf
- Previous versions
- Latest version
UKCA Declaration of Conformity
- 9106DoC_UKCA_100.pdf
- Latest version
Modbus configuration manual
- 9106_MCM_102.pdf
- 9106_MCM_101.pdf
- 9106_MCM_100.pdf
- Previous versions
- Latest version
Assessment report
- AssessmentReport_PR_2312098_V1R0_Series_9000.pdf
- Latest version
FMEDA report
- PR_9106_9107_060319_R025_FMEDA_V2R1.pdf
- Latest version
ISO 13849 declaration
- 9106_ISO_13849_declaration.pdf
- Latest version
EMC data
- 9000_EMC_data.pdf
- Latest version
PR default configurations
- PR_default_configurations.pdf
- Latest version
Safety note
Safety note
Environmental Conditions
Operating temperature | -20°C to +60°C |
Storage temperature | -20°C to +85°C |
Calibration temperature | 20...28°C |
Relative humidity | < 95% RH (non-cond.) |
Protection degree | IP20 |
Installation in | Pollution degree 2 & meas. / overvoltage cat. II |
Mechanical specifications
Dimensions (HxWxD) | 109 x 23.5 x 104 mm |
Dimensions (HxWxD) w/ PR 4500 | 109 x 23.5 x 131 mm |
Weight approx. | 250 g |
DIN rail type | DIN EN 60715/35 mm |
Wire size | 0.13...2.08 mm2 AWG 26...14 stranded wire |
Screw terminal torque | 0.5 Nm |
Vibration | IEC 60068-2-6 |
2...13.2 Hz | ±1 mm |
13.2...100 Hz | ±0.7 g |
Common specifications
Supply |
|
Supply voltage | 19.2...31.2 VDC |
Fuse | 1.25 A SB / 250 VAC |
Max. required power | ≤ 1.1 W / ≤ 1.9 W (1 ch. / 2 ch.) |
Max. power dissipation, 1 / 2 ch. | ≤ 0.8 W / ≤ 1.2 W |
Isolation voltage |
|
Test /working: Input to any | 2.6 kVAC / 300 VAC reinforced isolation |
Analog output to supply | 2.6 kVAC / 300 VAC reinforced isolation |
Status relay to supply | 1.5 kVAC / 150 VAC reinforced isolation |
Response time |
|
Response time (0...90%, 100...10%) | < 5 ms |
Programming | PR 4500 communication interfaces |
Signal dynamics, input | Analog signal chain |
Signal dynamics, output | Analog signal chain |
SMART bi-directional communication frequency range | 0.5...7.5 kHz |
Signal / noise ratio | > 60 dB |
Accuracy | Better than 0.1% of sel. range |
mA, absolute accuracy | ≤ ±16 μA |
mA, temperature coefficient | ≤ ±1.6 μA / °C |
Effect of supply voltage change on output (nom. 24 VDC) | < ±10 μA |
EMC immunity influence | < ±0.5% of span |
Extended EMC immunity: NAMUR NE21, A criterion, burst | < ±1% of span |
Input specifications
Current input |
|
Measurement range | 3.5...23 mA |
2-wire transmitter supply 9106B1x (Uo = 27.5 VDC) | >16 V / 20 mA |
2-wire transmitter supply 9106B2x (Uo = 25.3 VDC) | >15 V / 20 mA |
Sensor error detection: Loop break 4...20 mA | < 1 mA |
Input voltage drop, supplied unit | < 4 V @ 23 mA |
Input voltage drop, non-supplied unit | < 6 V @ 23 mA |
Output specifications
Current output |
|
Signal range | 3.5...23 mA |
Load (@ current output) | ≤ 600 Ω |
Load stability | ≤ 0.01% of span / 100 Ω |
Current limit | ≤ 28 mA |
Passive 2-wire mA output |
|
Effect of external 2-wire supply voltage variation | < 0.005% of span / V |
Max. external 2-wire supply | 26 VDC |
Status relay |
|
Relay function | N.C. |
Programmable low setpoint | 0...29.9 mA |
Programmable high setpoint | 0...29.9 mA |
Hysteresis for setpoints | 0.1 mA |
Max. voltage | 125 VAC / 110 VDC |
Max. current | 0.5 AAC / 0.3 ADC |
Max. voltage - hazardous installation | 32 VDC / 32 VAC |
Max. current - hazardous installation | 1 ADC / 0.5 AAC |
of span | = normal measurement range 4...20 mA |
Observed authority requirements
EMC | 2014/30/EU & UK SI 2016/1091 |
LVD | 2014/35/EU & UK SI 2016/1101 |
ATEX | 2014/34/EU & UK SI 2016/1107 |
RoHS | 2011/65/EU & UK SI 2012/3032 |
EAC | TR-CU 020/2011 |
EAC Ex | TR-CU 012/2011 |
EAC LVD | TR-CU 004/2011 |
Approvals
ATEX | DEKRA 11ATEX0244 X |
IECEx | DEK 11.0084X |
UKEX |
DEKRA 21UKEX0171X
DEKRA 23UKEX0107X |
c FM us | FM16US0465X / FM16CA0213X |
INMETRO | DEKRA 23.0003X |
c UL us, UL 61010-1 | E314307 |
c UL us, UL 913 | E233311 (only 9106xxx-U9) |
CCC | 2020322309003231 |
KCs | 21_AV4BO_0167X / 21_AV4BO_0168X (only 9106Bxx-KCs) |
EAC Ex | RU C-DK.HA65.B.00355/19 |
DNV Marine | TAA00000JD |
ClassNK | TA24034M |
SIL | SIL 2 / SIL 3 certified & fully assessed acc. to IEC 61508 |