Temperature / mA converter
9113B
- Input for RTD, TC and mA
- Active / passive mA output via the same two terminals
- 1 or 2 channels
- Can be supplied separately or installed on power rail, PR type 9400
- SIL 2-certified via Full Assessment
Advanced features
- Configuration and monitoring by way of detachable display front (PR 4500); process calibration and signal simulation.
- Copying of the configuration from one device to others of the same type via the display front.
- TC inputs can use either the internal CJC or a terminal with a built-in Pt100 sensor (PR 5910Ex, channel 1 / PR 5913Ex, channel 2) for higher accuracy.
- Advanced monitoring of internal communication and stored data.
- SIL 2 functionality is optional and must be activated in a menu point.
Application
- 9113Bxx can be mounted in the safe area or in zone 2 / Class 1, Division 2 and receive signals from zone 0, 1, 2 and zone 20, 21, 22 including mining / Class I/II/III, Division 1, Gr. A-G.
- Conversion and scaling of temperature (Pt, Ni and TC) and active current signals.
- The 9113 has been designed, developed and certified for use in SIL 2 applications according to the requirements of IEC 61508.
- Suitable for the use in systems up to Performance Level “d” according to ISO-13849.
Technical characteristics
- 1 green and 2 red front LEDs indicate operation status and malfunction.
- 2.6 kVAC galvanic isolation between input, output and supply.
Mounting
- The devices can be mounted vertically or horizontally without distance between neighbouring units.
Data sheet & Manuals
Data sheet
- 9113B.pdf
- Latest version
Manuals
- 9113V004_112_UK.pdf
- 9113V004_111_UK.pdf
- 9113V004_110_UK.pdf
- 9113V004_109_UK.pdf
- 9113BV004_108_UK.pdf
- 9113BV004_107_UK.pdf
- 9113BV004_106_UK.pdf
- 9113BV004_105_UK.pdf
- 9113BV004_104_UK.pdf
- 9113BV003_103_UK.pdf
- 9113BV002_102_UK.pdf
- 9113BV002_101_UK.pdf
- 9113BV001_100_UK.pdf
- 9113AV004_102_UK.pdf
- 9113AV004_101_UK.pdf
- 9113AV004_100_UK.pdf
- Previous versions
- Latest version
Manuals in Russian
- 9113V004_112_RU.pdf
- 9113V004_111_RU.pdf
- 9113V004_110_RU.pdf
- 9113V004_109_RU.pdf
- 9113L002_102_RU.pdf
- 9113BV004_108_RU.pdf
- 9113BV004_107_RU.pdf
- 9113BV004_106_RU.pdf
- 9113BV004_105_RU.pdf
- 9113BV004_104_RU.pdf
- 9113BV003_103_RU.pdf
- Previous versions
- Latest version
Manuals in Portuguese (Brazil)
- 9113V004_112_BR.pdf
- 9113V004_111_BR.pdf
- 9113V004_110_BR.pdf
- 9113V004_109_BR.pdf
- 9113BV004_108_BR.pdf
- 9113BV004_107_BR.pdf
- 9113BV004_106_BR.pdf
- 9113BV004_105_BR.pdf
- Previous versions
- Latest version
Manuals in Korean
- 9113V004_112_KR.pdf
- 9113V004_111_KR.pdf
- 9113V004_110_KR.pdf
- 9113V004_109_KR.pdf
- Previous versions
- Latest version
Safety manual (SIL)
- 9113_Safety_Manual_V9R0.pdf
- Latest version
Approvals & Certificates
ATEX certificate
- 9113B_07ATEX0148X_issue5.pdf
- 9113B_07ATEX0148X_issue4.pdf
- 9113B_07ATEX0148X_issue3.pdf
- 9113B_07ATEX0148X_issue2.pdf
- 9113B_07ATEX0148X_issue1.pdf
- Previous versions
- Latest version
IECEx certificate
- 9113BIEC_090052x_issue4.pdf
- 9113BIEC_090052x_issue3.pdf
- 9113BIEC_090052x_issue2.pdf
- 9113BIEC_090052x_issue1.pdf
- 9113BIEC_090052x_issue0.pdf
- Previous versions
- Latest version
UKEX certificate
- 9113B_23UKEX0109X_issue0.pdf
- 9113B_21UKEX0175X_issue0.pdf
- Previous versions
- Latest version
FM certificate
- 9113_FM19US0059X_FM19CA0032X.pdf
- Latest version
INMETRO certificate
- 9113_INMETRO_230005X_issue0.pdf
- 9113_INMETRO_160003X_issue1.pdf
- 9113_INMETRO_160003X_issue0.pdf
- Previous versions
- Latest version
UL certificate
CCC certificate
- 9113_CCC_2024_03.pdf
- Latest version
KCs certificate
- 9113B_KCs_21_AV4BO_0173X_0174X.pdf
- Latest version
SIL certificate
- 9113_004_SIL.pdf
- Latest version
DNV marine certificate
- DNV_9xxx_4510_4511.pdf
- 9000_DoC_DNV.pdf
- Previous versions
- Latest version
ClassNK certificate
- ClassNK-TA24034M_91xx_92xx_94xx.pdf
- Latest version
EAC declaration
- EAC_EMC_declaration_Ex_3000_5000_6000_9000.pdf
- Latest version
EAC Ex certificate
- EAC_Ex.pdf
- Latest version
Metrology Pattern Approval (MPA), Russia
- MPA_Russia.pdf
- Latest version
Supplementary documentation
EU Declaration of Conformity
- 9113DoC_EU_103_UK.pdf
- 9113DoC_EU_102_UK.pdf
- 9113DoC_EU_101_UK.pdf
- 9113DoC_EU_100_UK.pdf
- Previous versions
- Latest version
UKCA Declaration of Conformity
- 9113DoC_UKCA_100.pdf
- Latest version
Modbus configuration manual
- 9113_MCM_101.pdf
- 9113_MCM_100.pdf
- Previous versions
- Latest version
Assessment report
- AssessmentReport_PR_2312098_V1R0_Series_9000.pdf
- Latest version
FMEDA report
- PR_060319_R022_FMEDA_9113_V3R3.pdf
- Latest version
EMC data
- 9000_EMC_data.pdf
- Latest version
PR default configurations
- PR_default_configurations.pdf
- Latest version
Safety note
Safety note
Order form
Environmental Conditions
Operating temperature | -20°C to +60°C |
Storage temperature | -20°C to +85°C |
Calibration temperature | 20...28°C |
Relative humidity | < 95% RH (non-cond.) |
Protection degree | IP20 |
Installation in | Pollution degree 2 & meas. / overvoltage cat. II |
Mechanical specifications
Dimensions (HxWxD) | 109 x 23.5 x 104 mm |
Dimensions (HxWxD) w/ PR 4500 | 109 x 23.5 x 131 mm |
Weight approx. | 250 g |
DIN rail type | DIN EN 60715/35 mm |
Wire size | 0.13...2.08 mm2 AWG 26...14 stranded wire |
Stripping length | 5 mm |
Screw terminal torque | 0.5 Nm |
Vibration | IEC 60068-2-6 |
2...13.2 Hz | ±1 mm |
13.2...100 Hz | ±0.7 g |
Common specifications
Supply |
|
Supply voltage | 19.2...31.2 VDC |
Fuse | 400 mA SB / 250 VAC |
Max. required power | ≤ 0.8 W/≤ 1.4 W (1 ch./2 ch.) |
Max. power dissipation, 1 / 2 ch. | ≤ 0.8 W / ≤ 1.4 W |
Isolation voltage |
|
Test /working: Input to any | 2.6 kVAC / 300 VAC reinforced isolation |
Analog output to supply | 2.6 kVAC / 300 VAC reinforced isolation |
Status relay to supply | 1.5 kVAC / 150 VAC reinforced isolation |
Response time |
|
Temperature input, programmable (0...90%, 100...10%) | 1...60 s |
mA / V input (programmable) | 0.4...60 s |
Programming | PR 4500 communication interfaces |
Signal / noise ratio | Min. 60 dB (0...100 kHz) |
Signal dynamics, input | 24 bit |
Signal dynamics, output | 16 bit |
Accuracy | Better than 0.1% of sel. range |
EMC immunity influence | < ±0.5% of span |
Extended EMC immunity: NAMUR NE21, A criterion, burst | < ±1% of span |
Input specifications
RTD input |
|
RTD type | Pt10/20/50/100/200/250; Pt300/Pt400/500/1000; Ni50/100/120/1000 |
Cable resistance per wire | 50 Ω (max.) |
Sensor current | Nom. 0.2 mA |
Effect of sensor cable resistance (3-/4-wire) | < 0.002 Ω / Ω |
Sensor error detection | Programmable ON / OFF |
TC input |
|
Thermocouple type | B, E, J, K, L, N, R, S, T, U, W3, W5, LR |
Cold junction compensation (CJC) via ext. sensor in 5910 | 20...28°C ≤ ±1°C, -20...20°C / 28...70°C ≤ 2°C |
CJC via int. mounted sensor | ±(2.0°C + 0.4°C * Δt) |
Sensor error detection | Programmable ON or OFF (only wire breakage) |
Sensor error current: When detecting / else | Nom. 2 μA / 0 μA |
Current input |
|
Measurement range | 0...23 mA |
Programmable measurement ranges | 0...20 and 4...20 mA |
Input resistance | Nom. 20 Ω + PTC 50 Ω |
Sensor error detection | Programmable ON / OFF |
Output specifications
Current output |
|
Signal range | 0...23 mA |
Programmable signal ranges | 0...20/4...20/20...0/20...4 mA |
Load (@ current output) | ≤ 600 Ω |
Load stability | ≤ 0.01% of span / 100 Ω |
Sensor error indication | 0 / 3.5 / 23 mA / none |
NAMUR NE43 Upscale/Downscale | 23 mA / 3.5 mA |
Output limitation, on 4...20 and 20...4 mA signals | 3.8...20.5 mA |
Output limitation, on 0...20 and 20...0 mA signals | 0...20.5 mA |
Current limit | ≤ 28 mA |
Passive 2-wire mA output |
|
Max. external 2-wire supply | 26 VDC |
Effect of external 2-wire supply voltage variation | < 0.005% of span / V |
Status relay |
|
Max. voltage | 125 VAC / 110 VDC |
Max. current | 0.5 AAC / 0.3 ADC |
Max. AC power | 62.5 VA / 32 W |
Observed authority requirements
EMC | 2014/30/EU & UK SI 2016/1091 |
LVD | 2014/35/EU & UK SI 2016/1101 |
ATEX | 2014/34/EU & UK SI 2016/1107 |
RoHS | 2011/65/EU & UK SI 2012/3032 |
EAC | TR-CU 020/2011 |
EAC Ex | TR-CU 012/2011 |
EAC LVD | TR-CU 004/2011 |
Approvals
ATEX | KEMA 07ATEX0148 X |
IECEx | KEM 09.0052X |
UKEX |
DEKRA 21UKEX0175X
DEKRA 23UKEX0109X |
c FM us | FM19US0059X / FM19CA0032X |
INMETRO | DEKRA 23.0005X |
c UL us, UL 61010-1 | E314307 |
c UL us, UL 913 | E233311 (only 9113xx-U9) |
CCC | |
KCs | 21_AV4BO_0173X / 21_AV4BO_0174X (only 9113Bx-KCs) |
EAC Ex | EAEU KZ 7500361.01.01.08756 |
DNV Marine | TAA00000JD |
ClassNK | TA24034M |
SIL | SIL 2 certified & fully assessed acc. to IEC 61508 |
Need support to select the right product for your application?
Our sales engineers are ready to help specify the right device to meet your needs.
Reach out by phone to get in touch with us straight away – or use the contact form or quick quote function to send your RFQ directly from the website. You’ll get a response within 24 hours on normal business days.
You can expect to get a confirmed delivery date via email within 2 days after we have received your order.
As soon as your package leaves our warehouse, you’ll receive tracking details via email. And if you have any questions along the way we’re just a phone call or email away.
State-of-the-art manufacturing Our 8,500 sqm integrated and automated manufacturing campus in Denmark covers the entire value-chain from design and development to manufacturing. It allows us to design and optimize for testing and manufacturing thereby constantly driving quality up and costs down. |
Dedicated Presale / Aftersales
|
Product reliability |
Product deployment
|
Smart products
Check out our range of communication interfaces
|